Siemens A31003-51730-U103-7619 Special attributes of the type process, Controls, Attribute

Models: A31003-51730-U103-7619

1 336
Download 336 pages 29.09 Kb
Page 148
Image 148

The Elements of a DCO-Script

Controls

Attribute

 

Description

 

 

 

Blink interval

 

Editable combobox to specify the interval in milliseconds in

 

 

which the data elements of Listboxes blink (1000 milliseconds

 

 

= 1 seconds).

 

 

Here you can:

 

 

enter -1to use the interval of the parent Frame,

 

 

enter an integer, or

 

 

assign a Constant, Parameter or Variable of the data type

 

 

int.

 

 

The blink interval of a Listbox can be changed during the exe-

 

 

cution of the DCO-Script with the command „The Instruction

 

 

"SetListBoxBlinkTime"“.

 

 

Special attributes of the type "process"

 

 

 

TAN

 

Combobox to define the relation between several Listboxes of

 

 

the type "process".

 

 

Here you can:

 

 

-1to retain all existing entries or

 

 

a reference to a Listbox that has the type process,

 

 

If you enter a reference to a Listbox, the "TAN" will refer to the

 

 

entry selected for that Listbox. It is this entry that will generally

 

 

be applied when querying subordinate process information,

 

 

e.g. the subscribers of a broadcast marked in another Listbox.

 

 

 

Process colors

 

The field indicating the selected process color.

 

 

In this line, make a doubleclick under the column "Value" to

 

 

open the user window in which you can define the individual

 

 

process colors (see Section 4.6.3, "Process colors and Stan-

 

 

dard colors for process lists").

 

 

If no individual process colors are defined for the Listbox, the

 

 

regular standard colors will be used.

 

 

 

Table 5-61

Special attributes of Listbox

 

07/2010

5-80

OScAR-Pro Customized Operator, User Manual

Page 148
Image 148
Siemens A31003-51730-U103-7619 user manual Special attributes of the type process, Controls, Attribute, Description