Siemens A31003-51730-U103-7619 5.11.58The Instruction SetEditStatus, Instructions, Description

Models: A31003-51730-U103-7619

1 336
Download 336 pages 29.09 Kb
Page 222
Image 222

The Elements of a DCO-Script

Instructions

5.11.58The Instruction "SetEditStatus"

Description

Use this Function Instruction to edit the way in which an Edit field is output and used.

Arguments

Arguments

 

Description

 

 

 

Edit field

 

Editable combobox to specify the Edit field you want to edit

 

 

with regard to the way in which it is output and used.

 

 

Here you can:

 

 

enter the name of an Edit field direct or

 

 

select an Edit field from the list of all Edit fields that are

 

 

available.

 

 

 

Status

 

Editable combobox to specify the way in which the selected

 

 

Edit field is output and used.

 

 

Here you can:

 

 

choose 0 to hide the Edit field,

 

 

choose 1 to show the Edit field and enable entries,

 

 

choose 2 to output the Edit field but block all entries,

 

 

assign a Constant, Parameter or Variable of the data type

 

 

uint, or

 

 

assign the reference to a Control that has the data type

 

 

uint.

 

 

 

Table 5-126

The arguments of the Instruction SetEditStatus

 

07/2010

5-154

OScAR-Pro Customized Operator, User Manual

Page 222
Image 222
Siemens A31003-51730-U103-7619 5.11.58The Instruction SetEditStatus, Instructions, Description, Arguments, uint, or