Siemens A31003-51730-U103-7619 6.4.4Create the Lists, Create the Data list, Create the Filter

Models: A31003-51730-U103-7619

1 336
Download 336 pages 29.09 Kb
Page 282
Image 282

The planning and implementation of a DCO Project

Create the global objects

6.4.4Create the Lists

To fill the list field "Announcement list" located under the "Frames" child node "Announcement selection", and there under "Controls", you need a corresponding data container in form of a Data list. This Data list is filled with the instruction „The Instruction "GetMessages"“ and then copied to the list field with the instruction „The Instruction "SetListBoxList"“.

To restrict the value range of the administrated announcements, you also require a matching Filter.

Create the Data list

Create the following Data list (see Section 5.7.2, "Add a new Data list"):

Name

Data type

Description

 

 

 

Administrated

msg_id

Data list to accept the emergency messages administrated in OS-

emergency

 

cAR-Pro.

messages

 

 

 

 

 

Table 6-15

Create Data lists

Create the Filter

Create the below-listed Filter (see Section 5.7.7, "Add a new Filter"):

Name

Data type

IDs

 

Description

 

 

 

 

Emergency

msg_id

ID ranges

Info field for the event that is currently selected.

message Filter

 

from: 0000

 

 

 

to: 1999

 

 

 

Excluded IDs

 

 

 

1000

 

 

 

1001

 

 

 

1002

 

 

 

1003

 

 

 

 

 

 

Table 6-16

Create the Filter

 

 

 