Replacement of lamp unit

8.Insert the power cord plug into the wall outlet and then press the MAIN POWER switch.

Caution • If the power does not turn on (power indicator lamp (red) does not turn on) even after turning the MAIN POWER switch “I”, turn the MAIN POWER “O”, confirm that the lamp unit and door are installed correctly, and turn on again.

9. Press the “I” (POWER) button so that a picture is projected onto the screen.

10.Press the “MENU” button to display

the MAIN MENU screen, and then press the and buttons to move the cursor to select “OPTION”.

MAIN MENU

PICTURE

POSITION

LANGUAGE

OPTION

TEST PATTERN

SIGNAL LIST

:MENU SELECT ENTER:SUB MENU

11.Press the “ENTER” button to display

the “OPTION” screen, and then use the and buttons to select “LAMP1 RUNTIME” or “LAMP2 RUNTIME”.

12.Press and hold the “ENTER” button on the projector or the remote control

for approximately 3 seconds.

An item “LAMP RESET” will be added.

Note • When you press the “MENU” button, the lamp reset display disappears.

13. Press the and buttons to select for replacement lamp setting.

LAMP1: Replace the LAMP UNIT 1

LAMP2: Replace the LAMP UNIT 2

DUAL: Replace the LAMP UNIT 1 & LAMP UNIT 2

14.Press the “ENTER” button. When “OK?” is displayed, press the

“ENTER” button.

The used hours of the specified lamp unit will be reset to zero.

OPTION

 

ID

2

 

 

SETTING

FRONT-F

 

 

LAMP1 RUNTIME

1310h

 

 

LAMP2 RUNTIME

1310h

 

 

LAMP SELECT

DUAL

 

 

LAMP POWER

HIGH

 

 

LAMP COOLING TIME

SHORT

 

 

RS232C SETTING

 

 

 

RGB2 SELECT

RGB1 OUT

 

 

OSD POSITION

1

 

 

:MENU SELECT

 

 

ENTER:INITIALIZE

 

 

 

 

 

 

 

 

 

 

OPTION

 

 

 

ID

2

 

 

SETTING

FRONT-F

 

 

LAMP1 RUNTIME

1310h

 

 

LAMP2 RUNTIME

1310h

 

 

LAMP RESET

DUAL

 

 

LAMP SELECT

DUAL

 

 

LAMP POWER

HIGH

 

 

LAMP COOLING TIME

SHORT

 

 

RS232C SETTING

 

 

 

RGB2 SELECT

RGB1 OUT

 

:NENU SELECT

:CHANGE ENTER:EXECUTE

OPTION

OK?

 

ID

2

 

SETTING

FRONT-F

 

LAMP1 RUNTIME

1310h

 

LAMP2 RUNTIME

1310h

 

LAMP RESET

DUAL

 

LAMP SELECT

DUAL

 

LAMP POWER

HIGH

 

LAMP COOLING TIME

SHORT

 

RS232C SETTING

 

 

RGB2 SELECT

RGB1 OUT

ENTER:EXECUTE MENU:ESC

98

Page 98
Image 98
Panasonic PT-D7600U Press the Enter button. When OK? is displayed, press, An item Lamp Reset will be added