Siemens A31003-51730-U103-7619 Additional attributes of the Command KILLBDC, Frames, Attribute

Models: A31003-51730-U103-7619

1 336
Download 336 pages 29.09 Kb
Page 118
Image 118

The Elements of a DCO-Script

Frames

Attribute

 

Description

 

 

Additional attributes of the Command "KILLBDC"

 

 

Process context

Editable combobox to define the context in which the broad-

 

 

cast you want to end is running.

 

 

Here you can:

 

 

enter 0 to end broadcasts started by any user,

 

 

enter 1 to end all broadcasts that were NOT started by the

 

 

present user,

 

 

enter 2 to end all broadcasts that were started by the

 

 

present user,

 

 

enter 3 to end all broadcasts that were started by the

 

 

present user via the OScAR-Pro-TT Operator-Tool,

 

 

enter 4 to end all broadcasts that were started by the

 

 

present user via the OpenScape Alarm Response Profes-

 

 

sional,

 

 

use the selection field to assign a Constant, a Parameter

 

 

or a Variable of the data type uint, or

 

 

assign the reference to a Control that has the data type

 

 

uint.

 

 

 

Broadcast ID

 

Editable combobox to define the ID of the broadcast you want

 

 

to end.

 

 

Here you can:

 

 

leave the entry blank to end ALL broadcasts listed active

 

 

in the "Process context", or

 

 

enter a valid ID of a broadcast with up to 4 digits,

 

 

use the selection field to assign a Constant, a Parameter

 

 

or a Variable of the data type bdc_id, or

 

 

assign the reference to a Control that has the data type

 

 

bdc_id.

 

 

 

Table 5-41

Attributes and child nodes of the node "OScAR-Pro command templates"

 