AT Command Set
MC35_ATC_01_V05.00 Page 203 of 256 15.07.2002
8.16 AT^SMSO Switch off mobile station
Test command
AT^SMSO=?
Response
OK
Execute command
AT^SMSO
Response
^SMSO: MS OFF OK
Device will be switched off (power down mode)
Reference
Siemens
Note
Do not send any command after this command
8.17 AT^SMGR Read SMS message without set to REC READ
Test command
AT^SMGR=?
Response
OK
Execute command
AT^SMGR=
<index>
Parameter
See AT+CMGR
Reference
GSM 07.05
Note
The AT^SMGR command is a specific Siemens command with the same syn-
tax as “AT+CMGR Read SMS message”. The only difference is that the SMS
Message, which has REC_UNREAD status, is not overwritten to REC_READ.