Main
              AT Command Set
              Contents 
            Page
            Page
            Page
            Page
              Figures 
Tables               
0 Version History 
            Page
            Page
            Page
              1 Introduction 
1.1  Scope of the document               
1.2  Supported product versions and related documents 
              1.3 Conventions 
1.4  AT command syntax                 
1.4.1 Using parameters 
              1.4.2  Combining AT commands on the same command line 
1.4.3  Entering successive AT commands on separate lines               
1.5 Supported character sets 
              1.6 Flow control 
1.6.1  Softw are flow control (XON/OFF flow control)                 
1.6.2 Hardware flow control (RTS/CTS flow control) 
              2  Standard V.25ter AT Commands 
2.1  A/  Repeat previous command line                 
2.2  +++  Switch from data mode or PPP online mode to command mode 
              2.3  AT\Qn  Flow control 
2.4  ATA  Answer a call               
2.5  ATD  Mobile originated call to dial a number 
            Page
              2.6  ATD><mem><n>  Originate call to phone number <n> in memory <mem> 
            Page
              2.7  ATD><n>  Originate call to phone number selected from active memory 
              2.8  ATD><str>  Originate call to phone number in memory with correspond- ing field 
              2.9  ATDI  Mobile originated call to dialable ISDN number <n> 
              2.10 ATDL  Redial last telephone number used 
              2.11 ATE  Enable command echo 
2.12 ATH  Disconnect existing connection               
2.13 ATI  Display product identification information 
2.14 ATI[value]  Display additional identification information               
2.15 ATL  Set monitor speaker loudness 
2.16 ATM  Set monitor speaker mode                 
2.17 ATO  Switch from command mode to data mode / PPP online mode 
              2.18 ATQ  Set result code presentation mode 
2.19 ATP  Select pulse dialling                 
2.20 ATS0  Set number of rings before automatically answering the call 
              2.21 ATS3  Write command line termination character 
2.22 ATS4  Set response formatting character                 
2.23 ATS5  Write command line editing character 
              2.24 ATS6  Set pause before blind dialling 
2.25 ATS7  Set number of seconds to wait for connection completion                 
2.26 ATS8  Set number of seconds to wait for comma dial modifier 
              2.27 ATS10  Set disconnect delay after indicating the absence of data carrier 
2.28 ATS18  Extended error report                 
2.29 ATT  Select tone dialling 
              2.30 ATV  Set result code format mode 
2.31 ATX  Set CONNECT result code format and call monitoring               
2.32 ATZ  Set all current parameters to user defined profile 
2.33 AT&C  Set circuit Data Carrier Detec t (DCD) function mode               
2.34 AT&D  Set circuit Data Terminal Ready (DTR) function mode 
              2.35 AT&F  Set all current parameters to manufacturer defaults 
            Page
              2.36 AT&S  Set circuit Da ta Set Ready (DSR) function mode 
              2.37 AT&V  Display current configuration 
              2.38 AT&W  Store current configuration to user defined profile  
              2.39 AT+GCAP  Request complete TA capabilities list 
2.40 AT+GMI  Request manufacturer identification                 
2.41 AT+GMM  Request TA model identification 
              2.42 AT+GMR  Request TA revision identification of software status 
2.43 AT+GSN  Request TA serial number identification(IMEI)               
2.44 AT+ILRR Set TE-TA local rate reporting  
              2.45 AT+IPR Set fixed local rate 
              2.45.1 Autobauding 
              3  AT Commands for FAX 
C 0  data modem  e.g. TIA/EIA-602 or ITU V.25ter  C                
C
3.1  AT+FBADLIN  Bad Line Treshold               
3.2  AT+FBADMUL  Error Threshold Multiplier 
3.3  AT+FBOR  Query data bit order               
3.4  AT+FCIG  Query or set the Local polling id 
3.5  AT+FCLASS  Fax: Select, read or test service class               
3.6  AT+FCQ  Copy Quality Checking 
3.7  AT+FCR  Capability to receive               
3.8  AT+FDCC  Query or set capabilities 
              3.9  AT+FDFFC  Data Compression Format Conversion 
              3.10 AT+FDIS  Query or set session parameters 
              3.11 AT+FDR  Begin or continue phase C data reception 
3.12 AT+FDT  Data Transmission               
3.13 AT+FET  End a page or document 
3.14 AT+FK  Kill operation, orderly FAX abort                 
3.15 AT+FLID  Query or set the Local Id setting capabilities 
              3.16 AT+FMDL  Identify Product Model  
3.17 AT+FMFR  Request Manufacturer Identification                 
3.18 AT+FOPT  Set bit order independently 
              3.19 AT+FPHCTO  DTE Phase C Response Timeout 
3.20 AT+FREV  Identify Product Revision                 
3.21 AT+FRH  Receive Data Using HDLC Framing 
              3.22 AT+FRM  Receive Data 
3.23 AT+FRS  Receive Silence                 
3.24 AT+FTH  Transmit Data Using HDLC Framing 
              3.25 AT+FTM  Transmit Data 
3.26 AT+FTS  Stop Transmission and Wait               
3.27 AT+FVRFC  Vertical resolution format conversion 
              4  AT Commands originating from GSM 07.07 
4.1  AT+CACM  Accumulated call meter (ACM) reset or query               
4.2  AT+CALA  Set  alarm time   
            Page
            Page
              4.3  AT+CAMM  Accumulated call meter maximum (ACMmax) set or query 
              4.4  AT+CAOC  Advice of Charge information 
              4.5  AT+CBST  Select bearer service type 
              4.6  AT+CCFC  Call forwarding number and conditions control 
              4.6.1  Examples: Call forwarding 
            Page
              4.7  AT+CCLK  Real Time Clock 
              4.8  AT+CCUG: Closed User Group  
              4.9  AT+CCWA  Call waiting 
            Page
              4.10 AT+CEER  Extended error report 
              4.11 AT+CFUN  Set phone functionality 
            Page
            Page
              4.11.1 Wake up the ME from SLEEP mode 
              4.12 AT+CGMI Request manufacturer identification 
4.13 AT+CGMM  Request model identification                 
4.14 AT+CGMR  Request revision identification of software status 
              4.15 AT+CGSN  Request product serial number identification (IMEI) identical  to GSN 
4.16 AT+CHLD Call hold and multiparty               
4.17 AT+CHUP  Hang up call 
4.18 AT+CIMI  Request international mobile subscriber identity               
4.19 AT+CIND Indicator control 
            Page
              4.20 AT+CLCC  List current calls of ME 
              4.21 AT+CLCK  Facility lock 
            Page
              4.21.1 Examples: Enabling / disabling PIN 1 authentication 
              4.21.2 Examples: Phone lock 
            Page
              4.21.3 Examples: Call barring 
              4.22 AT+CLIP  Calling line identification presentation 
              4.23 AT+CLIR  Calling line identification restriction (by *# sequence) 
              4.24 AT+CLVL  Loudspeaker volume level 
              4.25 AT+CMEE  Report mobile equipment error 
              4.26 AT+CMER  Mobile equipment event reporting 
            Page
              4.27 AT+CMUT  Mute control 
              4.28 AT+CMUX  Enter multiplex mode 
              4.28.1 Restricted use of AT commands in Multiplex mode 
            Page
              4.29 AT+COPN  Read operator names 
              4.30 AT+COPS  Operator selection 
            Page
              4.31 AT+CPAS  Mobile equipment activity status 
              4.32 AT+CPBR  Read current phonebook entries 
              4.33 AT+CPBS  Select phonebook memory storage 
              4.34 AT+CPBW  Write phonebook entry 
              4.35 AT+CPIN  Enter PIN 
            Page
            Page
              4.35.1 What to do if PIN or password authentication fails? 
            Page
              4.36 AT+CPIN2  Enter PIN2 
            Page
              4.37 AT+CPUC  Price per unit and currency table 
              4.38 AT+CPWD  Change password 
            Page
            Page
              4.39 AT+CR  Service reporting control 
              4.40 AT+CRC  Set Cellular Result Codes for incoming call indication 
              4.41 AT+CREG  Network registration 
            Page
              4.42 AT+CRLP  Select radio link protocol param. for orig. non-transparent  data call 
              4.43 AT+CRSM  Restricted SIM access 
              4.44 AT+CSCS  Set TE character set 
              4.45 AT+CSNS  Single Numbering Scheme 
              4.46 AT+CSQ  Signal quality 
              4.47 AT+CSSN  Supplementary service notifications 
              4.48 AT+CUSD  Unstructured supplementary service data 
              4.49 AT+VTD=<n>  Tone duration 
4.50 AT+VTS  DTMF and tone generation (<Tone> in {0-9, *, #, A, B, C, D})               
4.51 AT+WS46 Select wireless network 
              5  AT commands originating from GSM 07.05 for SMS 
5.1  AT+CMGC  Send an SMS command               
5.2  AT+CMGD  Delete SMS message 
5.3  AT+CMGF  Select SMS message format               
5.4  AT+CMGL  List SMS messages from preferred store 
            Page
            Page
              5.5  AT+CMGR  Read SMS message 
            Page
            Page
              5.6  AT+CMGS  Send SMS message 
              AT Command Set
              5.7  AT+CMGW  Write SMS message to memory 
            Page
              5.8  AT+CMSS  Send SMS message from storage 
              5.9  AT+CNMA  New SMS message acknowledge to ME/TE, only phase 2+ 
              5.10 AT+CNMI  New SMS message indications 
            Page
            Page
              5.11 AT+CPMS  Preferred SMS message storage 
            Page
              5.12 AT+CSCA  SMS service centre address 
              5.13 AT+CSCB  Select cell broadcast messages 
              5.14 AT+CSDH  Show SMS text mode parameters 
              5.15 AT+CSMP  Set SMS text mode parameters 
              5.16 AT+CSMS  Select Message Service 
              6  GPRS AT commands in accordance with GSM 07.07 
6.1  Commands specific to MTs supporting GPRS                 
6.1.1  AT+CGATT  GPRS attach and detach 
              6.1.2  AT+CGACT  PDP context activate or deactivate 
              6.1.3  AT+CGDATA  Enter data state 
              6.1.4  AT+CGDCONT  Define PDP Context 
            Page
              6.1.5  AT+CGQMIN  Quality of Service Profile (Minimum acceptable) 
            Page
            Page
            Page
              6.1.6  AT+CGQREQ  Quality of Service Profile (Requested) 
            Page
            Page
            Page
              6.1.7  AT+CGSMS  Select service for MO SMS messages 
              6.1.8  AT^SGAUTH   Set type of authentication for PPP connection 
              6.2  Modem compatibility commands to MTs supporting GPRS 
6.3  ATD  *99# Request GPRS service               
6.3.1  ATD  *98#  Request GPRS IP service 
              6.3.2  ATH  Manual rejection of a network request for PDP context activation 
              6.4  Using GPRS AT commands (examples)  6.4.1 Miscellaneous AT commands 
            Page
              6.5  Using the GPRS dial command ATD 
              7  AT Commands for SIM Application Toolkit (GSM 11.14) 
              7.1  AT^SSTA Remote-SAT Interface Activation 
              7.2 ^SSTN Remote-SAT Notification 
              7.3  AT^SSTGI Remote-SAT Get Information 
              7.4  AT^SSTR Remote-SAT Response 
              8  Siemens defined AT commands for enhanced functions 
8.1  AT+CXXCID  Display card ID (identical to AT^SCID)               
8.2  AT^MONI  Monitor idle mode and dedicated mode 
            Page
              8.3  AT^MONP  Monitor neighbour cells 
              8.4  AT^SACM  Advice of charge and query of ACM and ACMmax 
              8.5 AT^SBC  Battery charging / discharging and charge control 
            Page
            Page
              8.6  AT^SCID  Display SIM card identification number 
              8.7  AT^SCKS  Set SIM connection presentation mode and query SIM con- nection status 
              8.8  AT^SCNI  List Call Number Information 
              8.9  AT^SCTM  Set critical operating temperature presentation mode or  query temperature 
            Page
              8.10 AT^SDLD  Delete the last number redial memory 
8.11 AT^SHOM  Display Homezone                 
8.12 AT^SLCD  Display Last Call Duration 
              8.13 AT^SLCK  Facility lock 
            Page
              8.14 AT^SMGL  List SMS messages from preferred storage 
              8.15 AT^SMGO  Set or query SMS overflow presentation mode or query SMS  overflow 
              8.16 AT^SMSO  Switch off mobile station 
8.17 AT^SMGR  Read SMS message without set to REC READ               
8.18 AT^SM20  Set M20 Compatibility 
              8.19 AT^SNFA  Set or query microphone attenuation 
              8.20 AT^SNFD  Set audio parameters to manufacturer default values 
              8.21 AT^SNFI  Set microphone path parameters 
              8.22 AT^SNFM  Mute microphone 
8.23 Audio programming model               
8.24 AT^SNFO  Set audio output (= loudspeaker path) parameter 
              8.25 AT^SNFPT   Call progress tones 
              8.26 AT^SNFS  Select audio hardware set 
              8.27 AT^SNFV  Set loudspeaker volume 
8.28 AT^SNFW  Write audio setting in non-volatile store               
8.29 AT^SPBC  Search the first entry in the sorted telephone book 
              8.30 AT^SPBG  Read entry from active telephone book via sorted index 
              8.31 AT^SPBS  Steps the selected phonebook alphabetically 
              8.32 AT^SPIC  Display PIN counter 
              8.33 AT^SPLM  Read the PLMN list 
              8.34 AT^SPLR  Read entry from the preferred operators list 
              8.35 AT^SPLW  Write an entry to the preferred operators list 
              8.36 AT^SPWD  Change password for a lock 
            Page
              8.37 AT^SRTC  Select, query, test ring tone parameters 
            Page
              8.38 AT^SSCONF   SMS Configuration 
              8.39 AT^SSDA   Set Display Availability  
              8.40 AT^SSYNC  Configure SYNC Pin 
            Page
              8.41 AT^STCD  Display Total Call Duration 
              9 APPENDIX 
9.1  Summary of ERRORS and Messages                 
9.1.1  Summar y of CME ERRORS related to GSM 07.07 
              9.1.2  Summar y of GPRS-related CME ERRORS 
              9.1.3  Summar y of CMS ERRORS related to GSM 07.05 
            Page
            Page
              9.1.4  Summar y of Unsolicited Result Codes (URC) 
            Page
            Page
              9.1.5 Result codes 
9.1.6  Cause Location ID for the extended error report (AT+CEER)               
9.1.7  GSM release cause for L3 Radio Resource (RR)  (AT+CEER) 
9.1.8  SIEMENS release cause for L3 Radio Resource (RR)  (AT+CEER)               
9.1.9  GSM release cause for Mobility Management (MM) (AT+CEER) 
              9.1.10 SIEMENS release cause for L3 Mobility Management (MM) (AT+CEER) 
9.1.11 GSM release cause for L3 Call Control (CC) (AT+CEER)               
9.1.12 SIEMENS release cause for L3 Call Control (CC) (AT+CEER) 
              9.1.13 SIEMENS release cause for L3 Advice of Charge (AOC)  (AT+CEER) 
9.1.14 GSM release cause for Supplementary Service call (AT+CEER)               
9.1.15 Siemens release cause for Call related Supplementary Services (CRSS)    (AT+CEER) 
9.1.16 GSM release cause for Session Management (SM) (AT+CEER)               
9.1.17 SIEMENS release cause for Session Management (SM) (AT+CEER) 
9.1.18 SIEMENS release cause for GPRS API  (AT+CEER)               
9.1.19 SIEMENS release cause for Embedded Netcore   (AT+CEER) 
              9.2  Summary of PIN requiring AT Commands 
            Page
              9.3  AT commands available before entering the SIM PIN 
            Page
              9.4  Standard GSM service codes 
            Page
              9.4.1  Additional notes on ^SCCFC, ^SCCWA, ^SCLCK 
            Page
              9.5  GSM and UCS2 alphabet tables