AT Command Set
MC35_ATC_01_V05.00 Page 58 of 256 15.07.2002
3.16 AT+FMDL Identify Product Model
Read command
AT+FMDL?
Send the model identification to the TA
Response
Gipsy Soft Protocolstack
OK
Reference
Siemens
Note
Used for Faxclass 2 only
3.17 AT+FMFR Request Manufacturer Identification
Read command
AT+FMFR?
Send the manufacturer identification to the TA
Response
SIEMENS
OK
Reference
Siemens
Note
Used for Fax class 2 only
3.18 AT+FOPT Set bit order independently
Write command
AT+FOPT=<opt>
Model specific command to set bit order independently of the understanding
which is "mirrored" and which is direct.
Response
OK
Parameter
<opt> 0 non-standard
1 standard
Reference
Siemens
Note
Used for Fax class 2 only