AT Command Set
MC35_ATC_01_V05.00 Page 208 of 256 15.07.2002
Test command
AT^SNFM=?
Response
^SNFM: (list of supported <mute>s) OK
Parameter
See write command
Read command
AT^SNFM?
Response
^SNFM: <mute> OK
Parameter
See write command
Write command
AT^SNFM=<mute>
Response
TA switches on/off the microphone
OK
Parameter
<mute> 0 Mute microphone
1 Microphone on
Reference
Siemens
Note
This command can be used in all audio modes (1 to 6) and dur ing a
voice call only.
Users should be aware that when they switch back and forth between dif-
ferent audio modes (for example handsfree on/off) the value of <mute>
does not change. This means that the status of mute operaton is retained
until explicitly changed.
As alternative, you can use the AT+CMUT command described in Chap-
ter 4.27
The following figure illustrates how the signal path can be adjusted with the AT command parameters
described in the Chapters 8.19 to 8.28.
A
D
A
D
-¥...0dB
speechcoder
(0dB; -6db,
-12dB; -18dB)
+0..42dB in
6dB-ste
p
s
1k
1k
1k
1k
2,65V
10uF
6,8R
6,8R
+
sideTone
A
T parameters
outCalibrate[n]
n = 0...4
inCalibrate
inBbcGain
outBbcGain
speechdecoder
Figure 1: AT audio programming model