Execute Command
AT^SRTC
The Execute command is intended for testing. It starts to play a mel-
ody from the audio output currently selected with the AT^SNFS com-
mand.
Response
OK
To stop the test use AT^SRTC again. During test playback, you can
enter the Write command to select another melody and adjust the
volume. Also, you can enter the Read command to check the type
and volume of the current ringing tone, and to view the status of play-
back (on / off).
The test ringing signal cannot be activated when an MTC is ringing
(ERROR).
If an MTC arrives during test playback, test ringing stops and “normal“
ringing is activated (RING).
Selecting <vol>=0 during the test, immediately stops playback. After
this, ringing tones will be muted until you change <vol> using the
Write command.
Reference