Silicon Laboratories SI2494/39, SI2493/57/34/15/04 manual U76 Bit Map, U77 Bit Map

Models: SI2493/57/34/15/04 SI2494/39

1 304
Download 304 pages 21.65 Kb
Page 115
Image 115

AN93

 

 

 

Table 74. U76 Bit Map

 

 

 

Bit

Name

Function

 

 

 

15:9

OHSR

Off-Hook Sample Rate for Intrusion Detection (40 ms units).

 

 

(1 second default)

 

 

 

8

FACL

Force ACL.

 

 

0

= While off-hook, ACL is automatically updated with LVCS value.

 

 

1

= While off-hook, ACL saves previously written value.

 

 

 

7:5

DCL

Differential Current Level (3 mA units, 6 mA default)

 

 

 

4:0

ACL

Absolute Current Level (3 mA units, 0 mA default)

 

 

 

 

U77 is a bit-mapped register that controls parameters relating to intrusion detection and overcurrent detection. U77 resets to 0x401E with a power-on or manual reset (see Table 75).

Bits 15:12 (IST) set the delay between the time the modem goes off-hook and the intrusion detection algorithm begins. This register has 250 ms increments, and the default value is 4 (1 sec).

Bit 11 (HOI) determines whether the host or modem responds to an intrusion. HOI = 0 (default) prevents the modem from hanging-up in response to an intrusion without host intervention. In this case, the host monitors U70 [2] (PPD) and takes the appropriate action when PPD is asserted indicating an intrusion. If HOI = 1, the modem hangs up immediately and will not go off-hook and dial when an intrusion is detected without host intervention. If %VN commands are set, HOI also causes the LINE IN USE result code upon PPD interrupt.

Bit 9 (AOC) = 0 (default) disables AutoOvercurrent. If enabled and an overcurrent condition is detected, the dc termination switches to 800 Ω, thus, reducing the current. If AOC = 0, the overcurrent condition is only reported by U70 [3] (OCD).

Bits 8:0 (OHT) set the delay between the time the modem goes off-hook and LVCS is read for an overcurrent condition. The default value for this register is 30 ms (see Table 75).

U78 is a bit-mapped register that controls intrusion detection blocking and intrusion suspend. U78 resets to 0x0000 with a power-on or manual reset (see Table 76).

Bits 15:14 (IB) controls intrusion blocking after dialing has begun. Table 76 defines the bit values and intrusion blocking.

Bits 7:0 (IS) set the delay between the start of dialing and the start of the intrusion algorithm when IB = 10 (see Table 76).

 

 

 

Table 75. U77 Bit Map

 

 

 

Bit

Name

Function

 

 

 

15:12

IST

Intrusion Settling Time (250 ms units) 1 second default.

11

HOI

Hang-Up On Intrusion.

 

 

0

= ISOmodem does not automatically hang up after an off-hook PPD interrupt.

 

 

1

= ISOmodem automatically hangs up after an off-hook PPD interrupt.

 

 

 

10

Reserved

Read returns zero.

 

 

 

9

AOC

AutoOvercurrent.

 

 

0

= Disable.

 

 

1

= Enable.

 

 

 

8:0

OHT[8:0]

Off-Hook Time (1 ms units) 30 ms default.

 

 

 

 

Rev. 1.3

115

Page 115
Image 115
Silicon Laboratories SI2494/39, SI2493/57/34/15/04 manual U76 Bit Map, U77 Bit Map