AN93

 

 

Table 39. Basic AT Command Set (Continued)

 

 

 

 

 

 

 

 

Command

 

 

Action

 

 

 

 

 

 

 

V1

 

Verbal result codes.

 

 

 

 

 

 

 

 

 

Call Progress Monitor (CPM)—This command controls which CPM

 

 

Xn

 

signals are monitored and reported to the host from the ISOmo-

 

 

 

 

dem (See Table 43).

 

 

 

 

 

 

 

X0

 

Basic results; disable CPM—Blind dial (does not wait for dial tone).

 

 

 

CONNECT message does not include speed.

 

 

 

 

 

 

X1

 

Extended results; disable CPM—Blind dial. CONNECT message

 

 

 

includes speed.

 

 

 

 

 

 

 

 

 

 

 

 

 

X2

 

Extended results and detect dial tone only. X1 with dial tone detec-

 

 

 

tion.

 

 

 

 

 

 

 

 

 

 

 

 

 

X3

 

Extended results and detect busy only. X1 with busy tone detec-

 

 

 

tion.

 

 

 

 

 

 

 

 

X4

 

Extended results, full CPM. X1 with dial and busy tone detec-

 

 

 

 

tion.

 

 

 

X5

 

Extended results—Full CPM enabled including ringback detection.

 

 

 

X4 with ring back detection.

 

 

 

 

 

 

 

 

 

 

 

Yn

 

Long space disconnect—Modem hangs up after 1.5 seconds or

 

 

 

more of continuous space while on-line.

 

 

 

 

 

 

*Y0

 

Disable data memory access by disallowing :W and :Q Com-

 

 

 

 

mands.

 

 

 

*Y1

 

Enable continuous DTMF tone (ATxY1D9 sends continuous “9”

 

 

 

tone).

 

 

 

 

 

 

 

 

 

 

 

 

 

*Y2

 

Enable continuous answer tone. To enable continuous answer

 

 

 

tone and answer, use ATxY2A.

 

 

 

 

 

 

*Y254

 

Enables Data Memory Access, i.e. allows :W and :Q commands.

 

 

 

 

 

 

 

Z

 

Hard reset—This command is functionally-equivalent to pulsing

 

 

 

the RESET pin low.

 

 

 

 

 

 

 

 

 

 

 

:E

 

Read from serial EEPROM. The format is AT:Ehhhh, where hhhh

 

 

 

is the EEPROM address in hexadecimal.

 

 

 

 

 

 

 

 

 

 

 

 

 

Interrupt read—This command causes the ISOmodem to report

 

 

:I

 

the lower eight bits of the interrupt register U70 (IO0). The CID,

 

 

 

OCD, PPD, and RI bits of this register are cleared, and the INT pin

 

 

 

 

 

 

 

 

(HIR1 INT flag in parallel or SPI mode) is deactivated on this read.

 

 

 

 

 

 

 

 

 

Read Quick Connect data.

 

 

 

 

hh is a hexadecimal value. Data are read as follows:

 

 

:LPhh

 

:LP0

d1...d8

 

 

 

 

:LP8

d9...d16

 

 

 

 

:LP10

d17...d24

 

 

 

 

:LP18

d25...d32

 

 

 

 

Write to serial EEPROM. The format is AT:Mhhhh,xxxx, where

 

 

:M

 

hhhh is the EEPROM address in hexadecimal and xxxx is the

 

 

 

 

EEPROM data in hexadecimal.

 

 

 

 

 

 

 