Silicon Laboratories SI2493/57/34/15/04, SI2494/39 manual Test the Prototype Si3018/10 Circuitry

Models: SI2493/57/34/15/04 SI2494/39

1 304
Download 304 pages 21.65 Kb
Page 246
Image 246

AN93

Prototype System

 

 

 

C1

 

 

Host

Host

Si24xx

Si3018

Discretes

 

Controller

UART

To

 

 

 

 

 

 

 

 

C2

 

Phone

 

 

 

 

Line

 

 

 

 

 

 

 

 

C1

 

 

PC

RS232

Si24xx

Si3018

Discretes

 

Transceiver

 

 

EVB

 

C2

 

 

 

 

 

 

 

Connect the prototype ground to the EVB ground.

Lift prototype C1 and C2 and EVB C1 and C2 so the Si3018 is disconnected from the Si24xx on both modems.

Connect EVB C1 and C2 to the Si3018 pad of prototype system C1 and C2.

Connect the phone line to the RJ11 jack on the prototype system.

Use PC and HyperTerm and attempt to establish a modem connection.

Figure 42. Test the Prototype Si3018/10 Circuitry

Prototype System

 

 

C1

 

 

Host

Host

Si24xx

Si3018

Discretes

Controller

UART

 

 

C2

 

 

 

 

C1

 

 

 

RS232

Si24xx

Si3018

Discretes

 

Transceiver

 

 

 

 

To

 

EVB

C2

 

Phone

 

 

 

Line

 

 

 

 

Connect the prototype ground to the EVB ground

Lift prototype and EVB C1 and C2 to decouple the line side from the DSP side. Do same on evaluation board.

Connect prototype system C1 and C2 to the Si3018 pad of EVB C1 and C2

Connect the phone line to the RJ11 jack on the EVB

Run the prototype system software to attempt a modem connection

Figure 43. Verify Prototype Si3018/10 Failure