Table 45. S-Register Descriptions (Continued)

Definition

S Register

 

 

Function

Default

Range

Units

(Decimal)

 

 

 

(Decimal)

 

 

 

 

 

 

 

41

V.34 symbol rate - Symbol rate for V.34 when using

0

0–5

 

the &T4 and &T5 commands.

 

 

 

 

0

– 2400

symbols/second

 

 

 

 

1

– 2743

symbols/second

 

 

 

 

2

– 2800

symbols/second

 

 

 

 

3

– 3000

symbols/second

 

 

 

 

4

– 3200

symbols/second

 

 

 

 

5

– 3429

symbols/second

 

 

 

 

A valid combination of symbol rate (S41) and data rate

 

 

 

 

(&G) must be selected.

 

 

 

 

Symbol Rate

Allowable Data Rates

 

 

 

 

2400

2400 – 21600

 

 

 

 

2743

4800 – 26400

 

 

 

 

2800

4800 – 26400

 

 

 

 

3000

4800 – 28800

 

 

 

 

3200

4800 – 31200

 

 

 

 

3429

4800 – 33600

 

 

 

42

Blacklisting—The ISOmodem does not dial the same

0 (disabled)

0–1

 

number more than two times in S44 seconds. An

 

 

 

 

attempt to dial a third time within S44 seconds results

 

 

 

 

in a BLACKLISTED result code. If the blacklist mem-

 

 

 

 

ory is full, any dial to a new number will result in a

 

 

 

 

BLACKLIST FULL result code. Numbers are added to

 

 

 

 

the blacklist only if the modem connection fails. The

 

 

 

 

%B command lists the numbers on the blacklists.

 

 

 

 

0

– disabled

 

 

 

 

 

1

– enabled

 

 

 

 

43

Dial attempts to blacklist.

4

0–4

 

When blacklisting is enabled with S42, this value con-

 

 

 

 

trols the number of dial attempts that result in a num-

 

 

 

 

ber being blacklisted.

 

 

 

44

Blacklist Timer

180

0–255

seconds

 

Period during which blacklisting is active

 

 

 

50

Minimum on-hook time—Modem remains on-hook for

3

0–255

seconds

 

S50 seconds. Any attempt to go off-hook is delayed

 

 

 

 

until this timer expires.

 

 

 

51

Number to start checking for an outside PBX line.

1

0–9

 

 

 

 

 

 

 

90