AN93

Table 45. S-Register Descriptions (Continued)

Definition

S Register

Function

Default

Range

Units

(Decimal)

 

(Decimal)

 

 

 

 

 

 

 

10

Carrier loss timer—The time a remote modem carrier

14

1–255

0.1 second

 

must be lost before the ISOmodem disconnects. Set-

 

 

 

 

ting this timer to 255 disables the timer, and the

 

 

 

 

modem does not time out and disconnect. If S10 is

 

 

 

 

less than S9, even a momentary loss of carrier causes

 

 

 

 

a disconnect. Use for V.22bis and lower data rates.

 

 

 

12

Escape code guard timer—Minimum guard time

50

10–255

0.02 second

 

before and after +++ to recognize a valid escape

 

 

 

 

sequence.

 

 

 

14

Wait for dial tone delay timer. This timer starts when

12

0–255

seconds

 

the W command is executed in the dial string.

 

 

 

24

Sleep inactivity time—This is the time the modem

0

0–255

seconds

 

operates in normal power mode with no activity on the

 

 

 

 

UART, parallel port, SPI port, or telephone line before

 

 

 

 

entering the low-power sleep mode and waking on

 

 

 

 

ring. The modem remains in the normal power mode,

 

 

 

 

regardless of activity, if the timer is set to 0.

 

 

 

30

Disconnect activity timer—Sets the length of time that

0

0–255

minutes

 

the modem stays online before disconnecting with no

 

 

 

 

activity on the UART, parallel port, SPI port, or tele-

 

 

 

 

phone line (ring, hookswitch flash, or Caller ID). This

 

 

 

 

feature is disabled if set to 0.

 

 

 

38

Hang up delay time—Maximum delay between receipt

20

0–255

seconds

 

of the ATH0 command and hang up. If time out occurs

 

 

 

 

before all data can be sent, the NO CARRIER (3)

 

 

 

 

result code is sent. An OK response is sent if all data

 

 

 

 

are transmitted prior to time out. This register applies

 

 

 

 

to V.42 mode only. S38=255 disables time out, and the

 

 

 

 

modem only disconnects if data are successfully sent

 

 

 

 

or carrier lost.

 

 

 

40

Data Pattern - Data pattern generated during &T4 and

0

0–2

 

&T5 transmit tests.

 

 

 

 

0 – All spaces (0s)

 

 

 

 

1 – All marks (1s)

 

 

 

 

2 – Random data

 

 

 

Rev. 1.3

89

Page 89
Image 89