Silicon Laboratories SI2493/57/34/15/04, SI2494/39 manual 180

Models: SI2493/57/34/15/04 SI2494/39

1 304
Download 304 pages 21.65 Kb
Page 180
Image 180

AN93

 

 

Table 112. <DLE> Simple Events (DCE-to-DTE) (Continued)

 

 

 

 

 

 

 

Format: <DLE>[Code]

 

 

 

 

Code

Hex

 

Description

 

 

 

 

o

0x6F

 

Receive buffer overrun

 

 

 

 

u

0x75

 

Transmit buffer underrun.

 

 

 

 

c

0x63

 

Fax Calling. DCE has detected T.30 1100 Hz tone.

 

 

 

 

e

0x65

 

Data Calling. DCE has detected V.25 1300 Hz tone.

 

 

 

 

h

0x68

 

Line voltage collapsed (phone line detached).

 

 

 

 

H

0x48

 

Line voltage restored (phone line reattached).

 

 

 

 

q

0x71

 

Presumed End of Message (QUIET).

 

 

 

 

l

0x6C

 

Loop current interruption.

 

 

 

 

b

0x62

 

Busy tone detected.

 

 

 

 

d

0x64

 

Dial tone detected.

 

 

 

 

r

0x72

 

Ringing tone detected.

 

 

 

 

p

0x70

 

Line voltage increased (parallel phone goes on-hook). DCE monitors loop current when

 

 

 

off-hook and line voltage when on-hook.

 

 

 

 

P

0x50

 

Line voltage decreased (parallel phone goes off-hook). DCE monitors loop current when

 

 

 

off-hook and line voltage when on-hook.

 

 

 

 

a

0x61

 

Fax or data answer. DCE has detected T.30 2100 Hz or V.21 1650 Hz answer tone.

 

 

 

 

f

0x66

 

Data answer. DCE has detected 2225 Hz, USB1 or AC answer sequence.

 

 

 

 

(

0x28

 

Negative (decreased) loop-current drift detected.

 

 

 

 

)

0x29

 

Positive (increased) loop-current drift detected.

 

 

 

 

180

Rev. 1.3

Page 180
Image 180