Silicon Laboratories SI2493/57/34/15/04, SI2494/39 manual AT+PQC Parameters, AT+PSS Parameters

Models: SI2493/57/34/15/04 SI2494/39

1 304
Download 304 pages 21.65 Kb
Page 172
Image 172

AN93

Table 108. AT+PQC Parameters

<Value>

Description

0Enable Short Phase 1 and Short Phase 2

1Enable Short Phase 1

2Enable Short Phase 2

3Disable Short Phase 1 and Short Phase 2

Table 109. AT+PSS Parameters

<Value>

Description

 

 

0

The DCEs decide whether or not to use

 

the short startup procedures. The short

 

startup procedures shall only be used if

 

enabled by the +PQC command.

 

 

1

Forces the use of the short startup proce-

 

dures on the next and subsequent con-

 

nections if they are enabled by the +PQC

 

command.

 

 

2

Forces the use of the full startup proce-

 

dures on the next and subsequent con-

 

nections independent of the setting of the

 

+PQC command.

 

 

172

Rev. 1.3

Page 172