Silicon Laboratories SI2494/39, SI2493/57/34/15/04 Stas, No Polarity Reversal, Protocol None

Models: SI2493/57/34/15/04 SI2494/39

1 304
Download 304 pages 21.65 Kb
Page 85
Image 85

AN93

Table 43. Result Codes (Continued)

Numeric1

Meaning

Verbal Response

X0

X1

X2

X3

X4

X5

32

UK CID State Tone Alert

STAS

X

X

X

X

X

X

 

Signal detected

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

33

Overcurrent condition

X5

X

X

X

X

X

X

40

Blacklist is full

BLACKLIST FULL (enabled

X

X

X

X

X

X

 

via S42 register)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41

Attempted number is black-

BLACKLISTED (enabled via

X

X

X

X

X

X

listed.

S42 register)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

42

No phone line present

NO LINE (enabled via %Vn

X

X

X

X

X

X

 

commands)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

43

Telephone line is in use

LINE IN USE (enabled via

X

X

X

X

X

X

 

%Vn commands)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

44

Polarity reversal detected

POLARITY REVERSAL

X

X

X

X

X

X

 

(enabled via G modifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

45

Polarity reversal NOT

NO POLARITY REVERSAL

X

X

X

X

X

X

detected

(enabled via G modifier)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

52

Link established at 56000

CONNECT 560006

 

X

X

X

X

X

60

Link established at 32000

CONNECT 320006

 

X

X

X

X

X

61

Link established at 48000

CONNECT 480006

 

X

X

X

X

X

63

Link established at 28000

CONNECT 280006

 

X

X

X

X

X

64

Link established at 29333

CONNECT 293336

 

X

X

X

X

X

65

Link established at 30666

CONNECT 306666

 

X

X

X

X

X

66

Link established at 33333

CONNECT 333336

 

X

X

X

X

X

67

Link established at 34666

CONNECT 346666

 

X

X

X

X

X

68

Link established at 36000

CONNECT 360006

 

X

X

X

X

X

69

Link established at 37333

CONNECT 373336

 

X

X

X

X

X

70

No protocol

PROTOCOL: NONE

 

Set with \V0 command.

 

 

 

 

 

 

 

 

 

 

75

Link established at 75

CONNECT 75

 

X

X

X

X

X

 

 

 

 

 

 

 

 

 

77

V.42 protocol

PROTOCOL: V427

 

Set with \V0 command.

 

79

V.42bis protocol

PROTOCOL: V42bis3

 

Set with \V0 command.

 

Notes:

1. Numeric mode: Result code <CR>.

2. Response for ATDn@mmm is silence is not found.

3. This message is supported only on the Si2493, Si2457, Si2434, and Si2415.

4. This message is supported only on the Si2493, Si2457, and Si2434.

5. X is not preceded by <CR><LF>.

6. This message is supported only on the Si2493 and Si2457.

7. V.44 with data compression disabled (+DS = 0) emits this result code.

8. If data compression is disabled (+DS = Q), the modem returns the message PROTOCOL:V42.

Rev. 1.3

85

Page 85
Image 85
Silicon Laboratories SI2494/39, SI2493/57/34/15/04 manual Stas, No Polarity Reversal, Protocol None