AN93

 

Table 39. Basic AT Command Set (Continued)

 

 

 

 

Command

 

 

Action

 

 

 

+VRA = n

 

Ringing Tone Goes Away Timer.

 

 

The ISOmodem only uses this command in call origination trans-

 

 

actions. This command sets the amount of time in 0.1 second units

 

 

the ISOmodem shall wait between Ringing Tone before it can

 

 

assume that the remote modem has gone off-hook. Default time

 

 

is five seconds.

 

 

 

+VRID = n

 

Repeat Caller ID.

 

 

n

Description

 

 

0

Display Caller ID information of the last incoming

 

 

call in formatted form.

 

 

1

Display Caller ID information of the last incoming

 

 

call in unformatted form.

 

 

 

+VRN = n

 

Ringing Tone Never Appeared Timer.

 

 

This command sets the amount of time in seconds the ISOmodem

 

 

will wait looking for Ringing Tone. If the ISOmodem does not

 

 

detect Ringing Tone in this time period, the ISOmodem shall

 

 

assume that the remote station has gone off-hook and return an

 

 

OK result code. Default time is 0 seconds.

 

 

 

+VRX

 

Receive Voice Stream.

 

 

Enable DTE receive of voice stream. The DCE will return a CON-

 

 

NECT response followed by the voice stream as defined by the

 

 

+VSM command. The DTE can issue a <DLE><!> or

 

 

<DLE><ESC> sequence to terminate the receive stream. The

 

 

DCE will return a <DLE><ETX> followed by an OK response for

 

 

<DLE><!> and <DLE><ESC> followed by an OK response for

 

 

<DLE><ESC>. The DCE can be configured to terminate the

 

 

stream using the DTE/DCE Inactivity Timer, which is configured

 

 

using the +VIT command. The DTE will need to process any

 

 

<DLE> shielded events present in the data stream. Any

 

 

<DLE><DLE> sequences can be preserved to allow less overhead

 

 

during playback of the stream with the +VTX command.

 

 

 

+VSD =

 

Silence Detection.

<sds>, <sdi>

 

<sds>

Noise level sensitivity

 

 

127

Less aggressive [more sensitive, lower noise lev-

 

 

 

els considered to be silence].

 

 

128

Nominal level of sensitivity.

 

 

129

More aggressive [less sensitive, higher noise lev-

 

 

 

els considered to be silence].

 

 

<sdi> sets the length of a time interval in 0.1 second units, which

 

 

must contain no or little activity, before the ISOmodem will report

 

 

(QUIET) (<DLE><q>). Default is five seconds.

 

 

 

 

Rev. 1.3

75