Silicon Laboratories SI2493/57/34/15/04 manual AEC Gain Calibration Dial Remote Telephone, Atz

Models: SI2493/57/34/15/04 SI2494/39

1 304
Download 304 pages 21.65 Kb
Page 218
Image 218

AN93

Table 135. AEC Gain Calibration – Dial Remote Telephone

Host to Modem

Modem to Host Result

Local Modem Actions

Commands / Data

Codes/Data

 

 

 

 

ATZ

OK

Reset the modem.

 

 

 

AT+FCLASS=8

OK

Enter voice mode.

 

 

 

AT:U1994

OK

Set SPCAL (U199 [2]) to enable calibration.

 

 

 

AT*Y254:W591

OK

Enable the SSI interface to the Si3000.

 

 

 

 

 

Configure Si3000 Register 1:

 

 

Disable speaker driver

AT:U72,0108

OK

Enable line output driver

 

 

Disable telephone instrument driver

 

 

Disable MBIAS output

 

 

 

 

 

Configure Si3000 Register 5:

 

 

10 dB Line In gain

 

 

Enable Line In

AT:U72,0597

OK

20 dB MIC input gain

 

 

Mute MIC input

 

 

Mute telephone instrument input

 

 

Enable IIR filter

 

 

 

 

 

Configure Si3000 Register 6:

AT:U72,065E

OK

0 dB RX PGA gain

Enable Line Out

 

 

 

 

Disable telephone instrument output

 

 

 

 

 

Configure Si3000 Register 7:

AT:U72,075E

OK

0 dB RX PGA gain

Enable SPKRL

 

 

 

 

Mute SPKRR

 

 

 

 

 

Configure Si3000 Register 9:

AT:U72,0900

OK

0 dB Line Out attenuation

 

 

0 dB Speaker output attenuation

 

 

 

AT:UB1,xxxx

OK

Use calibrated value from “Transmit Gain Calibration –

Speakerphone Disabled” section.

 

 

 

 

 

AT:UB5,xxxx

OK

Use calibrated value from “Receive Gain Calibration –

Speakerphone Disabled” section.

 

 

 

 

 

 

 

Setup off-hook voice mode. See Table 122 on page 198

AT+VLS=13

OK

for details. This command will switch the modem to off-

 

 

hook state.

 

 

 

AT+VSP=1

OK

Enable speakerphone voice path. See Table 136 for

details.

 

 

 

 

 

[Dial Number]

 

 

 

 

 

218

Rev. 1.3

Page 218
Image 218
Silicon Laboratories SI2493/57/34/15/04, SI2494/39 manual AEC Gain Calibration Dial Remote Telephone, Atz