Intel SBCEFCSW, SBFCM manual Switch diagnostic information, LED error codes

Models: SBCEFCSW SBFCM

1 170
Download 170 pages 11.82 Kb
Page 163
Image 163
Switch diagnostic information

Switch diagnostic information

The following LED error codes, I2C diagnostic register definitions, and alarms support the Fibre Channel Switch Module.

LED error codes

NOTE

See Chapter 6, “SBCEFCSW / SBFCM Parts listing,” on page 153 to determine which components should be replaced by a field service technician.

Heartbeat LED error codes

Action

 

 

2 blinks

Internal application failure (switch is inoperable, reset is required)

 

 

3 blinks

Fatal POST error (switch is inoperable)

 

 

4 blinks

Corrupt flash or configuration ("config restore" required to clear

 

fault condition)

 

 

NOTE

See Chapter 6, “SBCEFCSW / SBFCM Parts listing,” on page 153 to determine which components should be replaced by a field service technician.

Port LED error codes

Action

 

 

Fast blink

Port is inoperable (either hardware problem detected by POST,

 

E_Port isolated, or user set the port to "down" state)

 

 

I2C diagnostic register definitions

NOTE

See Chapter 6, “SBCEFCSW / SBFCM Parts listing,” on page 153 to determine which components should be replaced by a field service technician.

 

Progress indicators

Action

 

 

 

0x01

- Initialization

N/A

 

 

 

0x10

- Serial PROM test

N/A

 

 

 

0x20

- ASIC Register test

N/A

 

 

 

0x40

- Loopback test group 1

N/A

 

 

 

0x50

- Loopback test group 2

N/A

 

 

 

0x60

- Loopback test group 3

N/A

 

 

 

0x70

- Creating test results summary

N/A

(determining compromised vs. failed)

 

 

 

0xff - POST complete

N/A

 

 

 

149

Page 163
Image 163
Intel SBCEFCSW, SBFCM manual Switch diagnostic information, LED error codes, I2C diagnostic register definitions