Intel SBFCM, SBCEFCSW Port configuration defaults continued, Threshold configuration defaults

Models: SBCEFCSW SBFCM

1 170
Download 170 pages 11.82 Kb
Page 36
Image 36

Table 3. Port configuration defaults (continued)

Parameter

External port (0,15) default

Internal port (1-14) default

 

 

 

MFS_TOV

10

10

 

 

 

MSEnable

True

True

 

 

 

NoClose

False

False

 

 

 

IOStreamGuard

False

False

 

 

 

VIEnable

False

False

 

 

 

CheckAlps

False

False

 

 

 

Table 4. Threshold configuration defaults

Parameter

Default

 

 

ThresholdMonitoringEnabled

True

 

 

CRCErrorsMonitoringEnabled

True

RisingTrigger

25

FallingTrigger

1

SampleWindow

10

 

 

DecodeErrorsMonitoringEnabled

True

RisingTrigger

200

FallingTrigger

0

SampleWindow

10

 

 

ISLMonitoringEnabled

True

RisingTrigger

2

FallingTrigger

0

SampleWindow

10

 

 

LoginMonitoringEnabled

True

RisingTrigger

5

FallingTrigger

1

SampleWindow

10

 

 

LogoutMonitoringEnabled

True

RisingTrigger

5

FallingTrigger

1

SampleWindow

10

 

 

LOSMonitoringEnabled

True

RisingTrigger

100

FallingTrigger

5

SampleWindow

10

 

 

22Intel Blade Server Fibre Channel Switch Module SBCEFCSW / FC Expansion Card SBFCM Guide

Page 36
Image 36
Intel SBFCM, SBCEFCSW manual Port configuration defaults continued, Threshold configuration defaults