Intel SBFCM Set command, Authority, Syntax, Keywords, alarm clear, beacon state, config option

Models: SBCEFCSW SBFCM

1 170
Download 170 pages 11.82 Kb
Page 38
Image 38

Set command

Sets a variety of port and switch parameters.

Authority

Admin for all keywords except Alarm Clear, Beacon, and Pagebreak which are available with User authority.

Syntax

set

alarm clear

beacon [state]

config [option]

log [option]

pagebreak [state]

port [option]

setup [option]

switch [state]

Keywords

alarm clear

Clears the alarm log. This keyword is available with User authority.

beacon [state]

Enables or disables the flashing of the Port Logged-in LEDs according to [state]. This keyword is available with User authority. [state] can be one of the following:

On

Enables the flashing beacon.

Off

Disables the flashing beacon.

config [option]

Sets port, switch, alarm threshold, and zoning configuration parameters. See the “Set Config command” on page 26.

log [option]

Specifies the type of entries to be entered in the event log. See the “Set Log command” on page 32.

pagebreak [state]

Specifies how much information is displayed on the screen at a time according to the value given by [state]. This keyword is available with User authority. [state] can be one of the following:

On

Limits the display of information to 20 lines at a time.

Off

Allows continuous display of information without a break.

port [option]

Sets port state and speed for the specified port temporarily until the next switch reset or new configuration activation. See the “Set Port command” on page 34.

setup [option]

Changes SNMP and blade server configuration settings. See the “Set Setup command” on page 35.

24Intel Blade Server Fibre Channel Switch Module SBCEFCSW / FC Expansion Card SBFCM Guide

Page 38
Image 38
Intel SBFCM Set command, Authority, Syntax, Keywords, alarm clear, beacon state, config option, log option, port option