Configuration backup

Changes made to the switch module since it was manufactured can be saved to a file in nonvolatile memory. However, the backup file is lost if the switch module is reset. Use the File Transfer Protocol (FTP) user images procedures to save the configdata file to the network management workstation. (In FTP, no directory listing is available. The configuration backup file is always named configdata.) For information about SNMP configuration, see “SNMP configuration” on page 118 and “SNMP trap configuration.”

Configuration restore

Switch module configurations can be duplicated to easily propagate an identical configuration to other switch modules. Use the FTP User Images procedures with the Put command to send the previously saved (using config backup) configdata file to the switch module. In Telnet, use the Config Restore command to return the switch module configuration to the previously saved configuration. The switch module is automatically reset after a successful restore.

Restoring the factory default configuration

You can restore the switch module and port configuration settings to the factory default values. To restore the factory configuration on a switch module, click Switch / Restore Factory Defaults. Table 36 lists the factory default switch module configuration settings. Restoring the switch module to the factory default configuration does not restore the login name and password settings.

Table 36. Factory default configuration settings

Settings

Value

 

 

Module name

Fibre Channel switch module

 

 

Administrative state

Online

 

 

Domain ID

1

 

 

Resource allocation time

10000 milliseconds

out (RA_TOV)

 

 

 

Receiver transmitter

100 milliseconds

timeout (RT_TOV)

 

 

 

Error detect timeout

2000 milliseconds

(ED_TOV)

 

 

 

IP address

Switch module bay 3: 192.168.70.129

 

Switch module bay 4: 192.168.70.130

 

 

Subnet mask address

255.255.255.0

 

 

Gateway address

10.90.90.254

 

 

Boot method

Static

 

 

Contact

Undefined

 

 

Location

Undefined

 

 

Trap address

Trap 1: 10.0.0.1, Traps 2–5: 0.0.0.0

 

 

Trap community

Public

 

 

Read community

Public

 

 

Write community

Private

 

 

Port state

Online - external ad internal ports

 

 

Port speed

Auto-detect - external; 2G - internal

 

 