To determine whether your installation problem is caused by an attached Fibre Channel device, perform the following tasks:

1.Verify that all the Fibre Channel devices were turned on before you turned on the blade server.

2.Ensure that all cables are connected properly.

3.Verify that you configured your RAID storage subsystem using the utilities provided by the manufacturer

4.Use the SAN Utility Online Port Loopback Test to verify communication between the Expansion Card and the Fibre Channel Switch Module (refer to “Port testing” on page 117) Port testing should only be used on ports that are not actively transmitting data.

5.The crossPort Test referred to on the Hub/Switch PD maps is replaced by the Online Port Loopback Test and the External Port Loopback Test in the SAN Utility (refer to “Port testing” on page 117). Port testing should only be used on ports that are not actively transmitting data.