Intel SBCEFCSW, SBFCM manual IP configuration, Remote logging, Network Properties window

Models: SBCEFCSW SBFCM

1 170
Download 170 pages 11.82 Kb
Page 115
Image 115
Figure 16. Network Properties window

NOTE

The Read Community, Trap Community, and Write Community settings are like passwords; therefore, they are write-only fields. The current settings are not displayed.

Figure 16. Network Properties window

IP configuration

The IP configuration identifies the switch module on the Ethernet network and determines which start (boot) method to use. Start methods described in the following table are for external and internal ports. Table 23 describes the IP configuration parameters.

Table 23. IP configuration parameters

Parameter

Description

 

 

IP address

Internet protocol (IP) address for the Ethernet port.

 

Note: When the Blade Server Chassis SBCE is turned on, the management module

 

loads the following factory default Ethernet IP addresses:

 

• Switch module bay 3: 192.168.70.129

 

• Switch module bay 4: 192.168.70.130

 

 

Subnet mask

Subnet mask address for the Ethernet port. The default value is 255.255.255.0.

 

 

Boot method

Static - Uses the IP configuration parameters entered in the Switch Properties window.

 

 

Gateway

IP gateway address. The default value is 10.90.90.254.

 

 

Remote logging

The Remote Logging (syslog) feature enables saving of the log information to a remote host that supports the syslog protocol. When enabled, the log entries are sent to the syslog host at the IP address that you specify in the Logging Host IP Address field. Log entries are saved in the internal switch module log whether this feature is enabled or not.

101

Page 115
Image 115
Intel SBCEFCSW, SBFCM manual Remote logging, Network Properties window, IP configuration parameters