Important! Before making connections, make sure you have the correct cord set. Check it (read the label on the cable) against the following:

Power Cord Set

 

U.S.A. and Canada

The cord set must be UL-approved and CSA certified.

 

 

 

The minimum specifications for the flexible cord

 

are: - No. 18 AWG - not longer than 2 meters, or 16

 

AWG. - Type SV or SJ - 3-conductor

 

 

 

The cord set must have a rated current capacity

 

of at least 10 A

 

 

 

The attachment plug must be an earth-grounding

 

type with NEMA 5-15P (15 A, 125 V) or NEMA 6-

 

15P (15 A, 250 V) configuration.

Denmark

The supply plug must comply with Section 107-2-

 

D1, Standard DK2-1a or DK2-5a.

 

 

Switzerland

The supply plug must comply with SEV/ASE 1011.

 

 

U.K.

The supply plug must comply with BS1363 (3-pin

 

13 A) and be fitted with a 5 A fuse which complies

 

with BS1362.

 

 

 

The mains cord must be <HAR> or <BASEC>

 

marked and be of type HO3VVF3GO.75 (minimum).

 

 

Europe

The supply plug must comply with CEE7/7

 

(“SCHUKO”).

 

 

 

The mains cord must be <HAR> or <BASEC>

 

marked and be of type HO3VVF3GO.75 (minimum).

 

 

 

IEC-320 receptacle.

 

 

Veuillez lire à fond l'information de la sécurité suivante avant d'installer le Switch:

AVERTISSEMENT: L'installation et la dépose de ce groupe doivent être confiés à un personnel qualifié.

Ne branchez pas votre appareil sur une prise secteur (alimentation électrique) lorsqu'il n'y a pas de connexion de mise à la terre (mise à la masse).

Vous devez raccorder ce groupe à une sortie mise à la terre (mise à la masse) afin de respecter les normes internationales de sécurité.

Le coupleur d'appareil (le connecteur du groupe et non pas la prise murale) doit respecter une configuration qui permet un branchement sur une entrée d'appareil EN 60320/IEC 320.

8

Page 9
Image 9
SMC Networks SMCWHSG44-G manual Schuko