Fig. 5. Connecting Ethernet cables to SMCPWR-INJ3.

5.Check the “ACTIVE” LED: if power is successfully fed into the SMCWHSG44-G, the “ACTIVE” LED will be on (Red light); otherwise, the “ACTIVE” LED will be off.

6.If the electricity current is over the normal condition (Io°÷1.0 A), the “ACTIVE” LED will flash (Red light).

NOTE: SMCPWR-INJ3 is specially designed for SMC2582W-B, SMC2586W-G, and SMCWHSG44-G. The use of SMCPWR-INJ3 with other Ethernet-ready devices that are not compliant to IEEE 802.3af may cause damage to the devices.

1.6. Mounting the SMCWHSG44-G on a Wall

The SMCWHSG44-Gis wall-mountable.

1.Stick the supplied sticker for wall-mounting.

2.Use a ∆6.5mm driller to drill a 25mm-deep hole at each of the cross marks.

3.Plug in a supplied plastic conical anchor in each hole.

4.Screw a supplied screw in each plastic conical anchor for a proper depth so that the SMCWHSG44-Gcan be hung on the screws.

5.Hang the SMCWHSG44-Gon the screws.

Fig. 6. Mounting the SMCWHSG44-G on a wall.

24

Page 25
Image 25
SMC Networks manual Mounting the SMCWHSG44-G on a Wall, Mounting the SMCWHSG44-G on a wall