Note

You can also reset the camera by holding down the Shift button and pressing the numeric 0 button.

About Camera Tallies

When the camera supports the camera tally function (BRC series, etc.)

The camera tally lamp lights when the input from the camera is being used as program output.

Caution

Multiple settings are possible for the [Video Input Assign] [Control] setting.

In this case, the camera tally lights when the video from any of the source viewers for which the [Control] setting is made is being used for program output.

When using CCU, etc.

If the FACTORY USE connector of the unit is connected to the tally connector of a CCU (camera control unit), the tally lamp lights for any camera that is assigned to a PGM selection button or NEXT selection button on the front panel, as long as video from that camera is being used as program output (the button lights red).

Specifications of the FACTORY USE Connector

The specification of each pin is as shown below.

PinI/OSignalDescription

Number

Name

 

 

1

I

-

Unused

 

 

 

 

2

I

-

Unused

 

 

 

 

3

I

-

Unused

 

 

 

 

4

I

-

Unused

 

 

 

 

5

I

-

Unused

 

 

 

 

6

I

-

Unused

 

 

 

 

7

-

GND

GROUND

 

 

 

 

8

-

GND

GROUND

 

 

 

 

9

O

GPO0

GIP OUT1: Controls the tally of the camera assigned to

 

 

 

source number 1.

 

 

 

On: GND; Off: Open

 

 

 

 

10

O

GPO1

GIP OUT2: Controls the tally of the camera assigned to

 

 

 

source number 2.

 

 

 

On: GND; Off: Open

 

 

 

 

11

O

GPO2

GIP OUT3: Controls the tally of the camera assigned to

 

 

 

source number 3.

 

 

 

On: GND; Off: Open

 

 

 

 

Operations 3 Chapter