Checking the auto calibration results

If a warning message or error code appears in step 8 of “Performing auto calibration” (page 49), check the problem of the error and perform auto calibration again.

1 Press B/b to select “Yes,” then press when “Error occurred during calibration, press to investigate.” appears on the screen.

Confirm the details of the measurement results, then proceed with the appropriate remedy.

2 Press B/b to select “Retry,” then press .

3 Repeat steps 6 to 8 in “Performing auto calibration” (page 49).

To save measurement results that caused an error without taking a remedy

1Press B/b to select “No”, then press

when “Error occurred during calibration, press to investigate.” appears on the screen.

2Follow the steps in “Saving the measurement results” (page 52) to save the measurement results.

Started Getting

Message list after auto calibration measurement

Display

Explanation

 

Code 30

Headphones are connected. Remove the headphones and perform the auto calibration again.

 

 

 

 

 

Code 31

SPEAKERS (OFF/A/B/A+B) is set to OFF. Set it to others and re-perform the measurement.

 

 

 

 

 

Code 32

None of the speakers were detected. Make sure that the optimizer microphone is connected

 

 

properly and reperform the measurement.

 

 

If the optimizer microphone is connected properly but the error code appears, the optimizer

 

 

microphone cable may be damaged or improperly connected.

 

 

 

 

 

Code 33

• None of the front speakers are connected or only one front speaker is connected.

 

 

• The optimizer microphone is not connected.

 

 

• Either the left or right surround speakers is not connected.

 

 

• Surround back speakers are connected even though surround speakers are not connected.

 

 

Connect the surround speaker(s) to the SURROUND terminals.

 

 

• The surround back speaker is connected only to the SURROUND BACK SPEAKERS R

 

 

terminals. When you connect only one surround back speaker, connect it to the

 

 

SURROUND BACK SPEAKERS L terminals.

 

 

 

 

 

Code 34

Speakers are not placed in the proper position. Speakers or an optimizer microphone on the

 

 

right or left may be placed wrongly. See “1: Installing speakers” (page 22) and check the

 

 

speaker position.

 

 

 

 

 

Warning 40

The measurement has completed. However, the noise level is high. You may be able to

 

 

perform the measurement properly if you try it again, even though the measurement cannot

 

 

be performed in all environments. Try to perform the measurement in a quiet environment.

 

 

 

 

 

Warning 41

The input from the microphone is too big.

 

Warning 42

• It may be too close the distance between the speaker and the microphone.

 

 

Retry the measurement after setting apart from each other.

 

 

• It may be that the volume is too big when you use the receiver as a preamp.

 

 

 

 

 

Warning 43

The distance and position of a subwoofer cannot be detected. Or the angle of the speaker

 

 

position cannot be detected. This may be caused by noise. Try to perform the measurement

 

 

in a quiet environment.

 

 

 

 

 

 

continued

 

 

 

 

 

53GB