Adjusting the pincushion
The adjustment data becomes the individual setting for each input signal received.
1Press the GEOM button.
The “GEOMETRY” OSD appears.
GEOM
GEOMETRY
2 3 | 10 |
2Press the >?//button so that the picture edges become straight.
The OSD automatically disappears after about 10 seconds. To turn off the OSD, press the GEOM button again.
To reset, press the RESET button while the OSD is on. The picture rotation and the pincushion settings are both reset.
Adjusting the screen
1Press the SCREEN button.
The “SCREEN” OSD appears.
SCREEN |
| SCREEN |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| H CONVERGENCE |
|
|
| 85 |
| |
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| V CONVERGENCE |
|
|
| 7 2 |
| |
|
|
|
|
|
|
|
| CANCEL | MO I RE | OFF ON | ||||
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| MO I RE | ADJ |
|
|
| 0 |
|
|
|
|
|
|
|
|
| LAND I NG | ADJUST | |||||
|
|
|
|
|
|
|
| DEGAUSS | ON | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| SELECT | SET / ADJUST |
2Press the ¬./>button to select the parameter you want to adjust referring to the following.
The selected parameter turns yellow.
The OSD automatically disappears after about 30 seconds. To turn off the OSD, press the SCREEN button again.
To reset, press the RESET button while the OSD is on. The selected parameter is reset.
Convergence
The adjustment data becomes the common setting for all input signals received.
Press the >?//button so that the red or blue shadow disappears.
“H CONVERGENCE” (Horizontal convergence)
?. . . to move Red to the left and Blue to the right /. . . to move Red to the right and Blue to the left
“V CONVERGENCE” (Vertical convergence)
?. . . to move Red down and Blue up /. . . to move Red up and Blue down
Canceling the Moire
The adjustment data becomes the individual setting for each input signal received.
Press the >?//button to select “ON” for “CANCEL
MOIRE.”
If the picture becomes unclear
The picure may become unclear by canceling moire.
1Press the ¬./>button to select “MOIRE ADJ.”
2Press the >?//button to adjust beginning from 0 until the moire is minimum.
Landing
Correct when the color is not uniform due to influence from the earth’s magnetizm.
The adjustment data becomes the common setting for all input signals received.
First, degauss the screen, then display an entirely white picture for more than 20 minutes before the adjustment to adjust more accurately.
1Press the ¬./>button to select “DEGAUSS.”
2Press the >/button.
The screen is degaussed for about five seconds.
3Press the ¬./>button to select “LANDING.”
4Press the >/button.
The “LANDING” OSD appears on the screen.
| L AND I NG |
|
|
|
|
|
| ||
| SCREEN | MENU |
|
|
|
|
|
| |
| CENTER | TOP/ BOT |
|
|
|
| 25 |
| |
| LEFT | TOP |
|
|
| 85 |
| ||
|
|
|
|
|
| ||||
| R I GHT |
| TOP |
|
|
| 72 |
| |
|
|
|
|
|
|
| |||
| R I GHT | BOTTOM |
|
|
| 0 |
| ||
|
|
|
|
| |||||
| LEF T BOTTOM |
|
|
| 0 |
| |||
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| SELECT | ADJUST |
5Press the ¬./>button to select the position, and adjust by pressing the > ?//button.
To return to the “SCREEN” OSD, select “SCREEN MENU /” and press the >/button.
To reset, press the RESET button while the OSD is on. The selected parameter is reset.