4 Turn the MENU knob to display “FREE”, and then press the MENU knob.

You are now able to use clips and clip lists with user- defined names.

?006

FILE NAMING

 

TOP

NAMING FORM

:

FREE

AUTO

NAMING

:

TITLE

 

5 Turn the MENU knob to select “AUTO NAMING”,

 

 

 

 

 

and then press the MENU knob.

 

 

 

 

 

C****: Assign standard format clip names

 

 

3Chapter

 

 

TITLE: Assign clip titles as clip names.

andRecording

 

automatically.

6 Turn the MENU knob to display “TITLE”, and then

 

 

 

press the MENU knob.

Playback

 

The same name will now be given to newly recorded

 

clips.

 

 

 

 

 

 

 

Note

 

 

 

 

 

 

 

When the first letter of the title setting on the CLIP

 

 

TITLE menu is a space or period (.), the clip name is

 

 

the title string minus the first letter.

 

To enable clip and clip list renaming by FAM

 

Carry out steps 2 to 6 of “To assign clip names on this

 

unit”.

 

It is now possible to write, transfer, and rename clips and

 

clip lists with user-defined names over file access mode

 

(FAM) connections (see page 157).

 

To rename a clip, execute “Rename” on a clip with the

 

extension “.MXF” in the Clip folder.

 

The “.MXF” extension cannot be changed.

Fuji.MXF

Clip renaming by FAM is enabled

To rename a clip list, execute “Rename” on a clip list with the extension “.SMI” in the Edit folder.

The “.SMI” extension cannot be changed.

Sakura.SMI

Clip list renaming by FAM is enabled

To check clip names

Press the THUMBNAIL button to display the thumbnail screen, and select the clip whose name you want to check. The name of the selected clip appears at the upper left of the screen.

However, when the clip has a title, the title is displayed instead. Titles are enclosed in double quotation marks (“ ”).

See “Thumbnail Search” (page 76) for more information about the thumbnail screen.

Notes

Items in the upper left of the screen are displayed in the following order of priority.

Title > user-assigned clip name > standard clip name

Therefore, the display changes as follows, depending on whether a clip has a title.

-The title is displayed for clips recorded on this unit which have titles.

-The user-assigned or standard clip name is displayed for clips which do not have titles.

On XDCAM devices 1) with firmware earlier than version 1.4, clips with user defined names are displayed as “C5000” to “C9999” in the order of recording.

Clip names and clip list names are converted as follows for display in the thumbnail screen and the CLIP menu.

-If the clip name is longer than 15 characters, then the first 9 characters and the last 5 characters are displayed. Other characters are converted into s symbols.

-Lowercase characters are converted to uppercase.

-Kanji and other multibyte characters and some symbols are converted into s symbols. Sequences of s symbols are converted into a single s symbol. The following 21 symbols can be displayed.

: . ? ! # * / ( ) + - & @ = < > % " ; _ $

1)PDW-F350/F330, PDW-530/510, PDW-F70/F30, PDW-1500, PDW- R1, PDW-V1, PDW-D1, and PDW-70MD

Display example:

JumpingDolphin_No103

r

JUMPINGDO s NO103

72 Recording – Advanced Operations