Settings Detailed and Displays Menu 5 Chapter

MAINTENANCE menu

No.

Page

Item

Settings

Default

USER

Description

File

 

 

 

 

 

menu

 

 

 

 

 

 

 

page

 

 

 

 

 

 

 

 

 

 

08

BATTERY 2

TYPE DETECTION

AUTO /

AUTO

AUTO: Automatically detects

A

 

 

 

OTHER

 

 

battery type.

 

 

 

 

 

 

 

OTHER: Determines battery type

 

 

 

 

 

 

 

as always “Others”.

 

 

 

 

 

 

 

 

 

 

 

SEGMENT NO.7

11.0 to 17.0V

17.0V

 

When “Others” is determined,

 

 

 

 

(in 0.1 V

 

 

remaining battery capacity

 

 

 

 

steps)

 

 

indicator segment 7 lights when

 

 

 

 

 

 

 

below the set voltage.

 

 

 

 

 

 

 

[Battery battery capacity indicator

 

 

 

 

 

 

 

segment]

 

 

 

 

 

 

 

1 2 3 4 5 6 7

 

 

 

 

 

 

 

 

 

 

 

SEGMENT NO.6

 

16.0V

 

When “Others” is determined,

 

 

 

 

 

 

 

remaining battery capacity

 

 

 

 

 

 

 

indicator segment 6 lights when

 

 

 

 

 

 

 

below the set voltage.

 

 

 

 

 

 

 

 

 

 

 

SEGMENT NO.5

 

15.0V

 

When “Others” is determined,

 

 

 

 

 

 

 

remaining battery capacity

 

 

 

 

 

 

 

indicator segment 5 lights when

 

 

 

 

 

 

 

below the set voltage.

 

 

 

 

 

 

 

 

 

 

 

SEGMENT NO.4

 

14.0V

 

When “Others” is determined,

 

 

 

 

 

 

 

remaining battery capacity

 

 

 

 

 

 

 

indicator segment 4 lights when

 

 

 

 

 

 

 

below the set voltage.

 

 

 

 

 

 

 

 

 

 

 

SEGMENT NO.3

 

13.0V

 

When “Others” is determined,

 

 

 

 

 

 

 

remaining battery capacity

 

 

 

 

 

 

 

indicator segment 3 lights when

 

 

 

 

 

 

 

below the set voltage.

 

 

 

 

 

 

 

 

 

 

 

SEGMENT NO.2

 

12.0V

 

When “Others” is determined,

 

 

 

 

 

 

 

remaining battery capacity

 

 

 

 

 

 

 

indicator segment 2 lights when

 

 

 

 

 

 

 

below the set voltage.

 

 

 

 

 

 

 

 

 

 

 

SEGMENT NO.1

 

11.0V

 

When “Others” is determined,

 

 

 

 

 

 

 

remaining battery capacity

 

 

 

 

 

 

 

indicatorsegment 1 lights when

 

 

 

 

 

 

 

below the set voltage.

 

 

 

 

 

 

 

 

 

09

GENLOCK

GL H PHASE

(–99 to +99)

0

Sets horizontal phase for genlock.

A

 

 

H ADVANCE

0H / 90H

0H

 

Selects the output phase when an

 

 

 

 

 

 

 

SD reference signal is input.

 

 

 

 

 

 

 

0H: Make SD REF and HD OUT in

 

 

 

 

 

 

 

phase.

 

 

 

 

 

 

 

90H: Make the HD OUT phase

 

 

 

 

 

 

 

90H with offset respect to the

 

 

 

 

 

 

 

SD reference signal

 

 

 

 

 

 

 

(When an HD reference signal

 

 

 

 

 

 

 

is input, HD REF and HD OUT

 

 

 

 

 

 

 

are in phase.)

 

 

 

 

 

 

 

 

 

122 Menu Organization and Operation