First power off the unit, and then mount the lens using the following procedure.
(To mount a
For information about using the lens, refer to the operating instructions for the lens.
Lens mount
3 securing rubber
54 2 1
1Push the lens locking lever up and remove the lens mount cap from the lens mount.
2Align the center pin on the lens with the center slot in the lens mount, and insert the lens into the mount.
3Holding the lens in place, push the lens locking lever down to lock the lens.
Caution
If the lens is not firmly locked, it may come off while the camcorder is being used. This could cause a serious accident. Make sure the lens is firmly locked. It is recommended that the lens mount securing rubber be put on the lens locking lever as illustrated above.
Note
Mounting a
4 If a
Note
Connecting the lens cable to the LENS connector when the camcorder is powered may cause a malfunction of the camcorder or the lens. Before connecting the lens cable, be sure to check that the camcorder is powered off.
5 Secure the lens cable with the cable clamps. |
| ||
| |||
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
|
| |
|
| 2Chapter | |
If the focus is not precisely correct at the telephoto and | |||
Adjusting the Flange Focal Length | Preparations | ||
| |||
focal length (the distance from the lens mounting flange |
| ||
plane to the focusing plane). |
| ||
Once adjusted, no further adjustment is required unless the |
| ||
lens is changed. |
| ||
When carrying out the adjustment, use the supplied flange |
| ||
focal length adjustment chart as the subject. |
| ||
Flange focal length |
| ||
adjustment chart (supplied) |
|
Approx. 3 m
Note
If you use a subject with insufficient contrast, or move the camera or subject during adjustment, this will cause an adjustment error.
Carrying out the adjustmentWhen using the
Preparing the Lens 35