Apex Digital 5708009-C 1. Error Code Table Continued, Error Code Description, Solution, E020

Models: 5708009-C

1 160
Download 160 pages 45.78 Kb
Page 151
Image 151
E020

Apex 1 to 5.5 kW Generator

Table 6-1.Error Code Table (Continued)

Error Code

Error Code Description

Solution

 

 

 

E020

When the AC On LED is lit and the Interlock LED

Make sure that the

User interlock

is not lit, this means either the interlock is not

RF output cover is

open

satisfied or was interrupted. Both the interlock LED

firmly attached and

 

and the RF output will remain off until the interlock

ensure the interlock

 

is satisfied and an RF off command is given.

pins on the User port

 

 

are satisfied. Refer to

 

 

“Apex User Port

 

 

Options” on

 

 

page 4-2.

 

 

or

 

 

See “Interlock LED

 

 

is not Lit” on

 

 

page 6-5.

 

 

 

E025

When the user set target life ends, this error code is

Set new target life

Target life

reported. The output will not be turned off when the

then send RF On

expired

error is reported. However, once the output is turned

command to reset

 

off while this error is active, it cannot be turned on

unit.

 

until a new target life is set

 

 

 

 

E029 Ripple

The input line voltage is rectified internally to a bus

Verify that all three

Current Error

voltage. The Apex generator monitors the bus

phases are present on

(missing phase)

voltage for excessive ripple. If excessive ripple is

the input voltage

 

detected, this error is displayed. A missing phase on

lines and that the

 

the input line voltage or an unstable plasma may

plasma is stable. If

 

cause this error.

the problem persists

 

 

call AE Global

 

 

Support.

 

 

 

E033

The Apex unit monitors the rate at which the cold

To clear the error,

Temperature

plate temperature is changing. If the temperature

send RF OFF

Rate Threshold

increases too fast, the Apex generator protects itself

command to reset the

error

by shutting the output off.

unit; if error code

 

 

does not clear or if

 

 

the output does not

 

 

come on, the cooling

 

 

plate temperature

 

 

exceeded the over

 

 

temperature

 

 

shutdown threshold.

 

 

See “Overtemp LED

 

 

on Solid” on

 

 

page 6-4.

 

 

 

5708009-C

6-9

Page 151
Image 151
Apex Digital 5708009-C manual 1. Error Code Table Continued, Error Code Description, Solution, E020, E025, E033