Apex Digital 5708009-C 6. Host Port Commands for RS-232 with AE Bus Continued, Number of, Bytes

Models: 5708009-C

1 160
Download 160 pages 45.78 Kb
Page 97
Image 97
status

Apex 1 to 5.5 kW Generator

Table 4-6.Host Port Commands for RS-232 with AE Bus (Continued)

Command

 

 

Number of

Number of

 

 

Description

Host Data

Response

 

 

 

Bytes

Data Bytes

 

 

 

 

162

Requests report on process status; returning

0

4 data bytes

read

packet contains the following bytes arranged

 

4—8-bit

process

as follows.

 

values

status

1st status byte:

 

 

 

 

 

 

0

= unassigned

 

 

 

1

= unassigned

 

 

 

2

= recipe run is active

 

 

 

3

= unassigned

 

 

 

4

= unassigned

 

 

 

5

= output power (0 = off, 1 = on)

 

 

 

6

= RF on requested

 

 

 

7 = setpoint status (0 = within tolerance,

 

 

 

 

1 = out of tolerance)

 

 

2nd status byte:

0 = end of target life

1 = unassigned

2 = unassigned

3 = overtemperature

4 = unassigned

5 = unassigned

6 = unassigned

7 = interlock open

3rd status byte—fault flags

0 = nonmaskable interrupt

1 = bus fault

2 = high bus voltage

3 = unassigned

4 = low bus voltage

5 = out of setpoint

6 = unassigned interrupt

7 = unassigned

4th status byte—fault flags

0 = current limit

1 = contactor failure

2 = Profibus error

3 = unassigned

4 = unassigned

5 = unassigned

6 = unassigned

7 = CEX is locked

5708009-C

4-51

Page 97
Image 97
Apex Digital 5708009-C 6. Host Port Commands for RS-232 with AE Bus Continued, Number of, Description, Data Bytes