E050

Advanced Energy®

Table 6-1.Error Code Table (Continued)

Error Code

Error Code Description

Solution

 

 

 

E050

DeviceNet error

Verify DeviceNet

DeviceNet

 

cable is connected

Error

 

 

 

 

 

E051

PROFIBUS watch dog expired

Have the master

Profibus Watch

 

reestablish

Dog expired

 

communications and

 

 

send a “master reset”

 

 

to clear the error. See

 

 

“Profibus Watch Dog

 

 

Timer” on page 4-61.

 

 

 

E054

Profibus SPC has taken itself off-line

Cycle the Apex

Profibus SPC

 

unit’s power off and

has taken itself

 

on and reestablish

off-line

 

communications

 

 

between the master

 

 

and the slave.

 

 

 

E055

Profibus memory buffer overflow

Increase the time

Profibus

 

between packets

memory buffer

 

being sent to the unit

overflow

 

via the Profibus

 

 

master. See “Host

 

 

Port—Profibus” on

 

 

page 4-58.

 

 

 

E059

Profibus master released slave

To recover from the

Profibus master

 

“off state,” have a

released slave

 

Profibus master

 

 

establish

 

 

communications with

 

 

the Apex unit and

 

 

send a “master reset”

 

 

to clear the Apex

 

 

unit’s display. See

 

 

“Host Port—

 

 

Profibus” on

 

 

page 4-58.

 

 

 

E101

This indicates a configuration error.

Call AE Global

Measurement

 

Support.

PCB ID is

 

 

incorrect

 

 

 

 

 

6-10