Table 4-17.Response Message

Advanced Energy®

Table 4-17.Response Message

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

 

Bit 1

Bit 0

 

 

 

 

 

 

 

 

 

 

0

 

 

Forward Power Sense AI (LSB)

 

 

 

 

 

 

 

 

 

 

 

1

0

0

0

0

Forward Power Sense AO

 

 

 

 

 

 

(MSB)

 

 

 

 

 

 

 

 

 

 

 

2

 

 

Reflected Power Sense A1 (LSB)

 

 

 

 

 

 

 

 

 

 

 

3

0

0

0

0

Reflected Power Sense AI

 

 

 

 

 

 

(MSB)

 

 

 

 

 

 

 

 

 

 

 

4

 

 

Not Used AI (LSB)

 

 

 

 

 

 

 

 

 

 

 

5

0

0

0

0

Not Used AI (MSB)

 

 

 

 

 

 

 

 

 

 

6

 

 

Not Used AI (LSB)

 

 

 

 

 

 

 

 

 

 

 

7

0

0

0

0

Not Used AI (MSB)

 

 

 

 

 

 

 

 

 

 

8

 

 

 

INTS

 

TS

 

SPS

POS

 

 

 

 

 

 

 

 

 

 

Forward Power Sense 0 to 10 V; 10 V = maximum rated power linear Reflected Power Sense 0 to 10 V; 10 V = maximum reflected power linear POS = Power on Status; 1 = power output ON, 0 = power output OFF SPS = Setpoint Status; 1 = setpoint reached, 0 = setpoint not reached

TS = Temperature Status; 1 = GOOD, 0 = OVERTEMP INTS = Interlock Status; 1 = satisfied, 0 = open

Note: The 16-bit AO is shifted right four bits and the remaining first four bits are filled with 0s. This changes the 16-bit AO to a 12-bit AO with a value of 10 V = OFFFhex.

Note: Readbacks exceeding OFFFhex are limited to OFFFhex.