Table 4-6.Host Port Commands for RS-232 with AE Bus (Continued)

Command

 

Number of

Number of

 

Description

Host Data

Response

 

 

Bytes

Data Bytes

 

 

 

 

212

Returns the serial port 0 address and baud

 

3 data bytes

report serial

rate (set with CMD 69).

 

8-bit value

port 0

Note: The response contains 3 data bytes:

 

16-bit value

address

 

 

 

 

 

and baud

• byte 1:

 

 

rate

 

 

bits 0 through 4 = serial port address

 

 

 

 

 

 

(addresses 1 through 31 are

 

 

 

supported)

 

 

 

bits 5 and 6 = unused

 

 

 

bit 7 = communication protocol

 

 

 

(0 = RS-232, 1 = RS-485)

 

 

 

• Bytes 2 and 3 = baud rate

 

 

 

 

 

 