Apex 1 to 5.5 kW Generator

Table 4-6.Host Port Commands for RS-232 with AE Bus (Continued)

Command

 

Number of

Number of

 

Description

Host Data

Response

 

 

Bytes

Data Bytes

 

 

 

 

171

Requests external feedback limit (set by

 

2 data bytes

read ext

CMD 6)

 

16-bit value

feedback

Note: The response in data bytes 1 and 2

 

 

limit

 

 

represent the user external feedback

 

 

 

 

 

 

limit (LSB first). It returns the user

 

 

 

external feedback limit.

 

 

 

 

 

 

173 report

Reports dissipated power

 

2 data bytes

power

Note: The response in data bytes 1 and 2

 

16-bit value

dissipation

 

 

represent dissipated power (LSB first).

 

 

 

 

 

 

It returns dissipated power.

 

 

 

 

 

 

184

Requests how long the generator is

 

2 data bytes

read out-of-

programmed to produce output that is not

 

16-bit value

setpoint

equal to the programmed setpoint level

 

 

interval

before shutting output off (set with CMD 15).

 

 

 

Note: Data bytes 1 and 2 represent the

 

 

 

unsigned integer value for out of

 

 

 

setpoint time interval (LSB first). It

 

 

 

reports how many seconds the

 

 

 

generator will produce output that is

 

 

 

not equal to the setpoint before turning

 

 

 

the output off.

 

 

 

 

 

 

185

Requests what percentage the generator can

 

1 data byte

read

be out of setpoint before it starts the out-of-

 

8-bit value

allowable

setpoint timer (set with CMD 16).

 

 

deviation

Reports the allowable setpoint deviation

 

 

 

 

 

 

Note: The response reports the percentage (1

 

 

 

to 99) and the supply can be out of

 

 

 

setpoint before turning on the out-of-

 

 

 

setpoint timer.

 

 

 

 

 

 

5708009-C

4-53

Page 99
Image 99
Apex Digital 5708009-C manual Bytes Data Bytes 171, Dissipation, 184, 185