Table 4-9.Configuration of Profibus Upload Packet (Inbytes)

Byte

Description

 

 

4

Forward power low

 

 

5

Forward power high

 

 

6

Reflected power low

 

 

7

Reflected power high

 

 

8

Data byte (LSB)

 

 

9

Data byte

 

 

10

Data byte

 

 

11

Data byte

 

 

12

Data byte (MSB)

 

 

13

Data field definition

 

 

Bytes 0 and 1 of the upload packet contain information about the Apex generator; this information appears as status bits (or status “flags”). The following table defines these status bits:

Table 4-10.Upload Status Bytes

First Status Bit

8 = Control mode (with bit 9)

 

9

= Control mode (00 = User, 10 = Profibus)

 

10

= Setpoint status OK

 

11

= Reserved

 

12

= End of Target Life (EOTL)

 

13

= Active toggle bit

 

14

= Bus fault (high or low)

 

15

= Reserved

 

 

Second Status Bit

0 = Reserved

 

1

= Overtemperature condition

 

2

= Interlock mechanism open

 

3

= Momentary power failure

 

4

= Reserved

 

5

= Contactor not closed

 

6

= Reserved

 

7

= Output is on

 

 

 

 

In the first status byte, bit 13 (the active toggle bit) indicates, the status of the Profibus interface. After the Apex generator has powered up, this bit’s continuous change indicates that the Profibus interface is ready. During operation, a cessation of this change indicates that a communication problem exists.