Apex Digital 5708009-C manual 3. Output Specifications Continued, Description, of line regulation

Models: 5708009-C

1 160
Download 160 pages 45.78 Kb
Page 40
Image 40
Output power regulation accuracy

Advanced Energy®

Table 3-3.Output Specifications (Continued)

Description

PIN Option and Specification

 

 

Output protection—Apex generators sense and employ several parameters for protection

Reflected power limit

20% of maximum forward power for units rated for less

 

than 5500 W. 1000 W for 5500 W units. (PIN position 2

 

defines the maximum forward power rating for the unit.)

 

 

Dissipation limit

Maximum PA dissipation—non-latching alarm LED

 

 

Low/high line bus

Bus voltage outside spec window—latching alarm LED

 

 

Over-temperature

Over-temp condition—latching alarm LED preceded by

 

non-fault warning (user setting).

 

 

Output power range

All generators except the HALO will allow setpoints

 

between 1% and 100% of full scale. The exception is the

 

HALO 1.5k generator depicted by “L” in position 2 of the

 

PIN number. This allows setpoints from 5 watts to 1500

 

watts.

 

 

Output power regulation accuracy

 

 

Into 50 non-reactive load

• ± 1% of setpoint or ± 0.1% of full-rated output,

 

whichever is greater (all PIN position 2 options but K

 

and L)

 

±1% of setpoint or 0.25 W, whichever is greater

 

(PIN position 2, option K & L)

 

 

Into 3:1 VSWR non-

± 3% of setpoint (load power regulation), over all load

reactive load

phase angles, or ± 0.25% of full-rated output, which ever is

 

greater

 

 

Load regulation as a function

Less than 0.1% change in output power for 10% change in

of line regulation

ac line voltage

 

 

Load regulation as a function of temperature—(performance in accordance with the output power regulation accuracy)

Ambient air temperature

+5°C to +40°C

range

 

 

 

Cooling water temperature

+5°C to +35°C

range

 

 

 

Spurious outputs—Referenced to fundamental signal at full-rated output when operated in a 50 non-reactive load

Harmonic related

-40 dBc

 

 

Non-harmonic related

-50 dBc

 

 

3-8

5708009-C

Page 40
Image 40
Apex Digital 5708009-C 3. Output Specifications Continued, Description, PIN Option and Specification, of line regulation