Apex 1 to 5.5 kW Generator

Table 4-11.Profibus Host Port Commands (Continued)

Command

Description

Number of

Number of

 

 

Transmit

Response

 

 

Data Bytes

Data Bytes

 

 

 

 

9

Specifies the external feedback value that

3 data bytes

 

max ext

corresponds to 10 V on the User2 port;

16-bit value

 

feedback

requires data bytes arranged as follows:

8-bit value

 

 

Second/third byte = a 16-bit value in the range

 

 

 

of 500 to 5000.

 

 

 

Fourth byte = the number of decimal places (0

 

 

 

to 4) used to display the external feedback

 

 

 

signal on the operator panel.

 

 

 

 

 

 

11

Specifies which target is active; accepts a

1 data byte

 

select active

value of 1 to 4. (Readback command is 156.)

8-bit value

 

target

 

 

 

 

 

 

 

12

Sets the life (in kWh) of the active target.

3 data bytes

 

set target

Requires three data bytes (24-bit value):

24-bit value

 

life

Second, third, and fourth bytes = target life in

 

 

 

 

 

 

kWh.

 

 

 

Two decimals are implied—to get 1 kWh,

 

 

 

send a value of 100.

 

 

 

(Readback command is 157.)

 

 

 

 

 

 

14

Sets the active control mode of the generator;

1 data byte

 

control

possible choices are: 2 = host, 4 = User port

8-bit value

 

transfer

(analog).

 

 

 

 

 

 

15

Specifies how long the generator can produce

2 data bytes

 

out-of-

output that is not equal to the programmed

16-bit value

 

setpoint

setpoint level. Accepts a value of 0 to 599 s. (0

 

 

timer

disables the timer.) (Readback command is

 

 

 

184.)

 

 

 

 

 

 

16

Specifies a percentage that the generator can

1 data byte

 

allowable

be out of setpoint before it starts the out-of-

8-bit value

 

deviation

setpoint timer. Accepts a value of 1 to 99%.

 

 

 

(Readback command is 185.)

 

 

 

 

 

 

128

Requests the generator type; returns 4 ASCII

0

4 data bytes

supply type

characters.

 

4 ASCII

 

 

 

characters

 

 

 

 

129

Requests the output capacity of the generator;

0

4 data bytes

supply size

returning packet contains 4 ASCII characters.

 

4 ASCII

 

 

 

characters

 

 

 

 

 

 

 

 

5708009-C

4-67

Page 113
Image 113
Apex Digital 5708009-C manual Life, 184, Allowable