Table 3-4.Other Electrical Specifications (Continued)

Description

PIN Option and Specification

 

 

CEX In

• Required signal amplitude range of +2 dBm to +10

 

dBm

 

• Generator operating frequency ±0.005%

 

• Input impedance of 50 Ω, less than 1.5:1 VSWR

 

 

CEX Out

• Output signal amplitude range of +3 dBm to +7

 

dBm

 

• Generator operating frequency ±0.005%

 

• Output impedance of 50 Ω, less than 1.5:1 VSWR

 

 

COOLING SPECIFICATIONS

Table 3-5 describes the cooling specifications for the Apex generator.

Do not use de-ionized water for cooling purposes. De-ionized water causes both corrosion and erosion of cooling manifolds.

Table 3-5.Cooling Specification

Description

Specification

 

 

Temperature

+35°C (+95°F)

 

Note: Maximum water temperature at minimum flow rate

 

and maximum ambient air temperature (+40° C).

 

 

Flow rate

For 3kW 7.6 1pm (2 gpm)

Note: Varies according to the

For > 3kW 11.4 1pm (3 gpm)

 

option defined by PIN

 

position 2.

 

 

 

Pressure

 

 

 

Minimum pressure

For 3kW 0.9 Bar (13psi)

differential (supply to

For > 3kW 2 Bar (29 psi)

drain) required to

 

achieve specified

 

minimum flow rates)

 

 

 

3-10

5708009-C