Apex 1 to 5.5 kW Generator

Table 4-6.Host Port Commands for RS-232 with AE Bus (Continued)

Command

 

Number of

Number of

 

Description

Host Data

Response

 

 

Bytes

Data Bytes

 

 

 

 

201

Reports a count of unit on events

 

4 data bytes

report unit

Note: The response contains 4 bytes which

 

32-bit value

on events

 

 

represent a 32-bit count of events (LSB

 

 

 

 

 

 

first).

 

 

 

 

 

 

202

Reports a count of output on events

 

4 data bytes

report

Note: The response contains 4 bytes which

 

32-bit value

output on

 

 

represent a 32-bit count of events (LSB

 

 

events

 

 

first).

 

 

 

 

 

 

 

 

 

203

Reports a count of overtemp events

 

4 bytes

report

Note: The response contains 4 bytes which

 

32 bit value

overtemp

 

 

represent a 32-bit count of events (LSB

 

 

events

 

 

first).

 

 

 

 

 

 

 

 

 

205

Requests the amount of time (in seconds) that

 

4 data bytes

read run

the generator was producing output.

 

32-bit value

time

Note: The response contains 4 bytes which

 

 

 

 

 

 

represent a 32-bit time (LSB first). It

 

 

 

returns the amount of time in seconds

 

 

 

that the unit was producing output.

 

 

 

 

 

 

206

Requests the total amount of energy (in kWh)

 

4 data bytes

read total

delivered by the generator.

 

32-bit value

energy

Note: The response contains 4 bytes which

 

 

output

 

 

represent a 32-bit time (LSB first). It

 

 

 

 

 

 

returns the amount of energy in kilo

 

 

 

watt hours delivered by the unit.

 

 

 

 

 

 

210

Returns faults, warnings, and shutdowns

 

1 data byte

report fault

Note: The response contains 1 data byte

 

8-bit value

warnings

 

 

which represents fault warnings and

 

 

and

 

 

shutdowns.

 

 

shutdowns

 

 

 

• bit 0 indicates ripple warning

 

 

 

(0 = inactive, 1 = active)

 

 

 

• bit 1 indicates ripple failure

 

 

 

(0 = inactive, 1 = active)

 

 

 

• bit 2 indicates temperature rate failure

 

 

 

(0 = inactive, 1= active)

 

 

 

 

 

 

5708009-C

4-55

Page 101
Image 101
Apex Digital 5708009-C manual Bytes Data Bytes 201, 202, 203, 205, Time, 206, 210, Shutdowns