Analog outputs automatically set the output voltages to 0 V if too much time elapses after the last Poll Command message received by the device. At this timeout condition, the output of the generator shuts off and goes safe.
DEVICENET ROTARY SWITCHES: BAUD RATE AND ADDRESSING
The DeviceNet interface features three rotary switches, located on the rear, which are read each time the DeviceNet interface powers up. Use the Data Rate switch to select a baud rate: 125, 250, or 500 kbaud (0 = 125;1 = 250; 2 = 500 kbaud). The default is 500 kbaud. A switch setting in the PGM region lets you configure the baud rate through DeviceNet.
The signals available at the
Figure 4-10. DeviceNet control panel
Use the MSD and LSD switches to select the unit’s address (MAC ID). MAC IDs 0 through 63 are valid. Use the MSD switch to select the MAC ID’s most significant digit; use the LSD switch to select the MAC ID’s least significant digit. Switch settings greater than 63 (or in the “PGM” region of the MSD switch) let you configure the MAC ID through DeviceNet.
DEVICENET CONTROL PANEL LEDS
The rear panel of the Apex generator features two,
Devicenet Module Status LED
The MOD