Advanced Energy®
Table
Signal | Name | Description |
Pin |
|
|
|
|
|
4 | UNASSIGNED |
|
|
|
|
5 | ISOLATED GND | Isolated ground |
|
|
|
6 | ISOLATED +5 V | Isolated +5 V |
|
|
|
7 | UNASSIGNED |
|
|
|
|
8 | B | Data bus B |
|
|
|
9 | UNASSIGNED |
|
|
|
|
Profibus Type Files (GSD Files)
Type files are computer files that some Programmable Logic Controllers (PLCs) use to compile their Profibus programs. These files are
For older Siemens Profibus PLCs, the “type file” is proprietary to Siemens Energy & Automation (SE&A); hence, SE&A must create the type file. Newer Profibus PLCs use a
Type files are available on SE&A’s electronic Bulletin Board Services (BBS). You can download the type files through a modem connection. The telephone numbers for SE&A’s Profibus BBSs are:
•USA.: (423)
•Europe: 49 911 737972
You can download type files from a World Wide Web site maintained by the Profibus Trade Organization. The address is http:\\www.profibus.com.
Setting the Network Address with the Profibus DIP Switch
Use the DIP switch next to the Profibus port on the rear panel to set the Apex generator's address. Allowable addresses are even numbers between 0 and 126, selected in binary format.
To enter the unit's address, set the switch positions for binary representation, starting with the switch on the left and proceeding to the right (descending order of significance). The switches are numbered 1 through 8. Switch 1 is the most significant byte (MSB), and switch 8 is the least significant byte (LSB).