Apex Digital 5708009-C manual Error Codes, 1. Error Code Table, Error Code Description, Solution

Models: 5708009-C

1 160
Download 160 pages 45.78 Kb
Page 149
Image 149
ERROR CODES

Apex 1 to 5.5 kW Generator

If you answered yes to any one of the previous questions and the Apex passed the Internal Diagnostics test, the Apex is probably working properly and it may be reacting to an external load condition. You may want to consult your Process Engineer or system manufacturer to troubleshoot chamber related issues.

ERROR CODES

Error codes indicate a fault condition and report the most recent active error or alarm condition from the Apex unit. You can able to view error codes through a serial communication port such as RS-232. Another way to view error codes is through the Virtual Front Panel which provides an easy way to control an Apex generator through a personal computer. Call AE Global Support for information. The following table explains the specific error code meanings and solutions.

Table 6-1.Error Code Table

Error Code

Error Code Description

Solution

 

 

 

E000

No Error

 

 

 

 

E001

If the unit is unable to reach or maintain the

To avoid this error,

Out of setpoint

programmed output level within a specified amount

you can disable the

timer expired

of time, the output shuts off and this error code is

timer, increase the

 

reported. This timer is enabled and set through the

amount of allowable

 

serial communications port.

time, or try to

 

 

determine why the

 

 

unit is not reaching

 

 

setpoint. See “Power

 

 

Limit LED is Lit” on

 

 

page 6-5.

 

 

To clear this error

 

 

code, you must send

 

 

an RF OFF command

 

 

to reset the Apex

 

 

unit.

 

 

 

E004

This error is the same as when the Overtemp LED

See “Overtemp LED

Over

is on solid,

on Solid” on

Temperature

 

page 6-4.

Shutdown

 

 

 

 

 

5708009-C

6-7

Page 149
Image 149