Apex Digital 5708009-C 6. Host Port Commands for RS-232 with AE Bus Continued, Number of, Bytes

Models: 5708009-C

1 160
Download 160 pages 45.78 Kb
Page 92
Image 92
Table 4-6.Host Port Commands for RS-232 with AE Bus (Continued)

Advanced Energy®

Table 4-6.Host Port Commands for RS-232 with AE Bus (Continued)

Command

 

Number of

Number of

 

Description

Host Data

Response

 

 

Bytes

Data Bytes

 

 

 

 

8

Specifies the output setpoint level for

2 data bytes

1

setpoint

whatever method of output regulation has

16-bit value

 

 

been selected. Accepts a value of 0 to 8000

 

 

 

W (for the 8 kW option) or 0 to 10000 W (for

 

 

 

the 10 kW option) when forward or load

 

 

 

power regulation is selected. Regular units

 

 

 

report in units of watts. HALO units report in

 

 

 

units of tenths of watts.

 

 

 

 

 

 

9

Specifies the external feedback value that

3 data bytes

 

max ext

corresponds to 10 V on the User port;

16-bit value

 

feedback

requires data bytes arranged as follows:

8-bit value

 

 

• First/second byte = a 16-bit value in the

 

 

 

range of 500 to 5000.

 

 

 

• Third byte = the number of decimal

 

 

 

places (0 to 4) used to display the

 

 

 

external feedback signal on the operator

 

 

 

panel.

 

 

 

 

 

 

11

Specifies which target is active; accepts a

1 data byte

1

select

value of 1 to 4. (Readback command is 156.)

8-bit value

 

active

 

 

 

target

 

 

 

 

 

 

 

12

Sets the life (in kWh) of the target you

5 data bytes

1

set target

specify. Requires five data bytes arranged as

8-bit value

 

life

follows:

32-bit value

 

 

• First byte = the target number

 

 

 

• Second, third, fourth, fifth bytes = target

 

 

 

life in kWh

 

 

 

Note: A decimal is implied—to get 1 kWh,

 

 

 

send a value of 100.

 

 

 

(Readback command is 157.)

 

 

 

 

 

 

14

Sets the active control mode of the generator;

1 data byte

1

control

possible choices are: 2 = host, 4 = User port

8-bit value

 

transfer

(analog).

 

 

 

 

 

 

15

Specifies how long the generator can produce

2 data bytes

1

out-of-

output that is not equal to the programmed

16-bit value

 

setpoint

setpoint level. Accepts a value of 0 to 599 s.

 

 

timer

(Readback command is 184.)

 

 

 

 

 

 

4-46

5708009-C

Page 92
Image 92
Apex Digital 5708009-C 6. Host Port Commands for RS-232 with AE Bus Continued, Number of, Description, Data Bytes