Table 4-6.Host Port Commands for RS-232 with AE Bus (Continued)

Command

 

Number of

Number of

 

Description

Host Data

Response

 

 

Bytes

Data Bytes

 

 

 

 

130

Requests the version number of the

0

7 data bytes

read

mainframe software. The returning packet

 

7 ASCII

mainframe

contains 7 ASCII characters—a 7-digit

 

characters

software

number. This command is used in

 

 

version

conjunction with CMD 198 to obtain the

 

 

number

version/revision number of the mainframe

 

 

 

software.

 

 

 

 

 

 

140

Requests the serial Host port time-out value

0

2 data bytes

report host

(002 to 500 representing 0.02 to 5.00 s).

 

16-bit value

time-out

 

 

 

value

 

 

 

 

 

 

 

154

Requests regulation mode (set with CMD 3).

 

1 data byte

report

Returning values:

 

8-bit value

regulation

• 6 = Forward

 

 

mode

 

 

• 7 = Delivered or Load

 

 

 

 

 

 

• 8 = External (DC Bias)

 

 

 

 

 

 

155

Requests control mode (set by CMD 14).

0

1 data byte

read control

Returning values: 2 = host, 4 = analog

 

8-bit value

method

 

 

 

 

 

 

 

156

Requests the number of the active target (set

0

1 data byte

read active

by CMD 11)

 

8-bit value

target

 

 

 

 

 

 

 

157

Requests the amount of life remaining in the

1 data byte

4 data bytes

read target

target you specify (set by CMD 12). This

8-bit value

32-bit value

life

command requires 1 data byte to specify the

 

 

 

number of the target you request (1 to 4).

 

 

 

Note: A decimal is implied—100 = 1 kWh,

 

 

 

 

 

 

4-50

5708009-C

Page 96
Image 96